2
Technical data
2.1
General data and operating conditions
Conformity and approval
Conformity
CE
Ambient conditions
Degree of protection
DIN EN 60529
Mechanical
IEC/EN 60721−3−3
(operation/storage/trans
port)
Vibration
Shock
Climatic
IEC/EN 60068−2−1
IEC/EN 60068−2−2
IEC/EN 60068−2−14
Storage/transport
Operation of 17.3"
devices
Operation of 24"
devices
Site altitude
Transport
Storage/operation
2.2
Electrical data
Supply
Voltage
[V DC]
Current at 24 V
[A]
Celeron®
[A]
Core i5
[A]
Max. starting
[A]
current
Fuse
Celeron®
[A]
Core i5
[A]
Screen
Resolution
[pixels
]
Aspect ratio
Brightness
[cd/m
2
]
Contrast
Lenze ¯ EDKVX00P242 ¯ 2.0
2006/95/EC
Low−Voltage Directive
2004/108/EC
EMC Directive
IP65
3M4
3M4
−20 °C ... +60 °C; 10 % ... 85 % air humidity without condensate
0 °C ... +50 °C; 10 % ... 85 % air humidity without condensate
0 °C ... +45 °C; 10 % ... 85 % air humidity without condensate
< 12000 m amsl
< 3000 m amsl
Industrial PC v800−P
43.9 cm (17.3")
61 cm (24")
−
3
4
4
−
4, slow−blow
6, slow−blow
6, slow−blow
400
600:1
1000:1
Technical data
General data and operating conditions
43.9 cm (17.3")
24 (19.2
28.8)
1920 x 1080
16:9
250
400
600:1
Monitor v200−P
61 cm (24")
2
−
−
3
4, slow−blow
−
−
250
1000:1
2
EN
19