7. THE FIRST HEATING:
- Warm up the sauna stove after installation to remove the smells of paints and oil.
At the same time, arrange the ventilation of the sauna.
8. CARE OF THE SAUNA STOVE:
- The stove stones should be checked from time to time and the damaged stones
replaced with the new ones.
- It is worthwhile leaving the stove switched on for a moment after the sauna.
9. VENTILATION OF THE SAUNA:
- The ventilation of the sauna must be arranged as effectively as possible to achieve
sufficient oxygen and freshness. The best way is that the fresh air is directed near
to the sauna stove (not closer than 50 cm).
- The ventilating air pipe must be equipped with an adjustable valve.
- The size of the bleed valve must be at least twice as big as the ventilating air pipe.
The bleed valve can be installed on the wall opposite the sauna stove at least 20 cm
higher than the ventilating air pipe.
10. CONSTSRUCTION OF THE SAUNA:
- The sauna must be well insulated thermally, especially the ceiling thorough which
the warmth mostly tends to dissipate. Owing to the damp, it is recommended that
the thermal insulation of the sauna is protected with material which does not allow
damp to penetrate, for instance aluminium foil. The cladding must always be wood.
11. SPARE PARTS:
7
8
9
10
11
12
1
2
3
Stove type
1
Stove type
2
N 18
N18
3
N 21
4
N21
5
6
N 24
N
N24
N 27
N27
N 30
N30
N 33
N33
Resistance
Model
Resistance
Model
1,2,3,4,5,6
1 1500 W / 230 V
1,2,3,4,5,6,
1 1500W/230V
7, 8,9,10,11,12 1 1500 W / 230 V
7,8,9,10,11,12
1 1500W/230V
1,3,5,7,9,11
1 1500 W / 230 V
1,3,5,7,9,11
1 1500W/230V
2,4,6,8,10,12 2 2000 W / 230 V
2,4,6,8,10,12
2 2000W/230V
1,2,3,4,5,6
2 2000 W / 230 V
1,2,3,4,5,6
2 2000W/230V
7,8,9,10,11,12 2 2000 W / 230 V
2 2000W/230V
7,8,9,10,11,12
1,2,3,4,5,6
2 2000 W / 230 V
1,2,3,4,5,6
2 2000W/230V
7,8,9,11
2 2000 W / 230 V
7,9,11
2 2000W/230V
8,10,12
2 3000 W / 230 V
2 3000W/230V
8,10,12
1,3,5,7,9,11
2 2000 W / 230 V
1,3,5,7,9,11
1,3,5,7,9,11
1,3,5,7,9,11
2 2000W/230V
2,4,6,8,10,12 3 3000 W / 230 V
3 3000W/230V
2,4,6,8,10,12
2,4,6,8,10,12
2,4,6,8,10,12
1,3,5
2 2000 W / 230 V
1,3,5,
2 2000W/230V
2,4,6
3 3000 W / 230 V
3 3000W/230V
2,4,6
7,8,9,10,11,12 3 3000 W / 230 V
3 3000W/230V
7,8,9,10,11,12