3. INSTALLATION
3.1 INSTALLATION OF THE SAUNA STOVE
- The sauna stove is fastened by two legs to the floor.
- When installing the sauna stove the protection distances must be considered
- The connection of the sauna stove to the electrical network must be carried out
by a qualified electrician in accordance with the valid regulations.
- A rubber cable of type H07RN-F or similar must be used as a connection cable.
The cross-sectional surface and the size of the fuse of the cable are shown in Table 1.
Table 1. The installation data of Narvi-Ultra Big
SAUNA STOVE
Model Effect Group effect Volume Height Sides In front In front Ceiling Floor
min max
kW
kW
kW
m
3
N 18
18
9
9
18
N 21
21
9
12
24
N 24
24
12
12
27
N 27
27
12
15
30
N 30
30
15
15
40
N 33
33
15
18
46
SAUNA
MINIMUM DISTANCES
From the stove
A**)
B**)
min
min
min
m
3
cm
cm
cm
30
210
16
10
36
210
16
10
40
210
16
10
46
220
20
10
56
220
20
10
66
220
20
10
Figure 1. The protection distances
of the sauna stove N
Power Connecting cable Connecting Front fuse
C**)
D**)
E**)
unit
cm
cm
cm
mm
20
140
68
5 x 10
20
140
68
5 x 10
20
140
68
5 x 16
20
150
68
5 x 16
20
150
68
5 x 16
20
150
68
5 x 16
CABLES
mm
cable
Group1 Group2
for the
stove
5x2.5
5x2.5
5x2.5
5x2.5
5x4
5x2.5
5x4
5x4
5x2.5
5x4
5x6
5x2.5
5x6
5x6
5x2.5
5x6
5x10
5x2.5
FUSES
Group fuse
Group1 Group2
A
A
A
3x35
16
16
3x35
16
25
3x50
25
25
3x50
25
25
3x50
25
25
3x50
25
25
**) See Figure 1