Herunterladen Inhalt Inhalt Diese Seite drucken

Conductor Interrupt (Error Code 3); Short Circuit (Error Code 4) - Metz Kapri plus Bedienungsanleitung

Kabel- und installationstester
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6. Operation

6.8 Conductor Interrupt (Error Code 3)

In case of conductor interrupts at the tested installation or cable,
the red conductor LED (F) of the KAPRi plus displays all interrupted
conductors. Select the number of conductors of the installation by
using the Selection Switches (C) before you start the test run.
The error code for conductor interrupt is digit 3.

6.9 Short Circuit (Error Code 4)

If the KAPRi plus detects a short circuit between two or more con-
ductors, the conductor LED (F) will display all interconnected con-
ductors. If more than one short circuit is detected, they are display-
ed as individual errors. Even if the KAPRi plus Test Box is not termi-
nated the KAPRi plus Mainframe displays short circuits.
The error code for short circuit is digit 4.
Note
Terminating resistors used in an installation are also recognized as
short circuits.