slab which will be protected against
groundwater or earth moisture – sealing gas-
ket set 83023 must be used (accessory). If
the concrete slab will be equipped with a
membrane or sheet – this sheet is to be
connected to the Staufix SWA body with the
counter flange supplied with the 83023. In
the case that a water proof concrete is being
used then the heavy duty Kautschuk seal (in-
cluded with the 83023) is inserted and then
fixed tight with the counter flange. Please in-
stall the Kautschuk flange properly so that
the pre-drillled holes in the Kautschuk seal
2017/02
match up with the screw holes of the counter flange. (see illustration 6). In the case that the
water tight slab barrier is penetrated by drainage pipes or conduit pipes to the SWA, it should
be assured that these penetration are also water / moisture tight.
Installation diagram (example umpfix F)
Concrete floor with moisture protective
sheet
BWS
*
Seal seat (83023)
• Counterflange
➀ KESSEL-Pumpfix F, Staufix FKA,
Dichtungsset (83023)
• Sealing sheet
Staufix SWA, Controlfix
- Gegen ansch
- Dichtungsbahn
➁ Groundwater protection set (83023)
➂ Extension section (83071)
Installation with extension section Article Number 83071
The height of the groundwater sealing flange can be adjusted on-site if using the 83071 ex-
Compression seal
flange
tension section. No more than 2 extension sections should be used to assure proper
Pressdichtungs-
access to the backwater valve for service or repair. It may be required that the upper section
ansch
Illustr. 6
is shortened to meet on-site installation heights / requirements.
2. Installation
Tiles
Screed
Fliesen
Insulation
Estrich
Concrete slab
Dämmung
Protective concrete
Betonboden
Moisture protective
Schutzbeton
sub slab
Abdichtung
Unterbeton
2
3
4
1
F
23
S
Concrete floor with waterproof concrete
Tiles
Screed
Fliesen
Insulation
Estrich
BWS *
Waterproof
Dämmung
concrete floor
Betonboden
4
2
5
➃ DN 100 intermediate section with stain-
less steel counter flange (27198)
➄ Elastomeric sealing barrer (27159)
1
010-841