Operation

Watch the display while making all settings.
1. Setting the time of day
Press and hold down the button "CLOCK"; with the key "HOUR" key (for hours) and the button
"MIN" (for minutes) to set the correct time by pressing repeatedly. If you hold down the buttons
"HOUR" and "MIN" the fast set starts.
2. To set the day(s) of the week
Press and hold down the "CLOCK" button; using the "DAY" button the correct weekday or
group can be set by briefl y pressing it repeatedly.
3. To set the timer:
1. Press the "TIMER" button briefl y. You are now in Block 1. "ON ----" appears in the display.
2. With the "DAY" button, the weekday or the group, for which the connected load is to be
switched on or off, can be set.
3. Set the desired time, with the "HOUR" and "MIN" buttons, when the connected load is to be
switched "ON".
4. Press the "TIMER" button again. "OFF - - - -" now appears in the display.
5. Using the „DAY", as well as "HOUR" and "MIN" buttons, set the desired time, as well as
week day or group, when the connected load is to be switched "OFF".
The other 7 blocks can now be set, one after the other, as described above!
6. Press the "CLOCK" key; the current time and weekday are once again shown in the display.
4. Function settings „ON" ⇔ „AUTO" ⇔ „OFF"
To set the required operating mode, press the "MANUAL" button, until the desired status
appears in the display. Watch the bottom line of the display to see which operating mode is set.
ON
The connected load is switched on manually and the red LED lights up.
AUTO
The timer settings will run automatically.
OFF
The connected load is switched off manually and the red LED goes out.
5. To cancel/change entries:
Press the "TIMER" button again to call up the data that is already set. Use the "DAY",
"HOUR" and "MIN" buttons to correct incorrect settings as well as to make changes in the
respective blocks 1-8.
6. Reset:
Use the "RESET" button to delete all the settings.
Disposal
Electrical and electronic products do not belong in the household waste! Please
dispose of the device when it is no longer of use, according to the current statutory
requirements.
Technical Data
Operating voltage: ............. 200 - 240 V/AC, 50 - 60 Hz
Switching capacity: ............ Resistive load: Max. 16 A
Other loads: Max. 8 A
Switching cycles: ............... 8 x on/off
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2012 by Conrad Electronic SE.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis