Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Disposal; Technical Data - Truma BC 416 IU Gebrauchsanweisung, Einbauanweisung

Battery charger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Maintenance

The power supply must always be disconnected before
performing any maintenance work on the device.
Clean the device and the ventilation slits with a dry and fluff-
free cloth.

Disposal

The device must be disposed of in line with the administra-
tive regulations of the respective land in which it is used.
National regulations and laws (in Germany, for example,
the Altfahrzeug-Verordnung [old vehicle directive]) must be
observed.

Technical Data

Power supply
AC voltage 230 V / 50 Hz, single-phase
Range approx. 180 V – 250 V / 50 – 60 Hz
Output current (charging current battery)
Charging current max. 16 A, arithmetic mean value, electroni-
cally controlled according to the IUoU charging reference line
Output voltage
DC voltage 12 V
Charging process
Automatic
Automatic switching (main charging process)
OFF at a battery voltage of 14.4 V, charging current < 14.5 A
Automatic switching (afterloading phase)
10 hours constant 14.4 V for gel batteries / AGM.
4 hours constant 14.4 V for liquid electrolyte batteries.
Automatic switching (trickle charging)
Trickle charging constant 13.8 V
Temperature-dependent control (optional)
The values of the automatic switching device refer to a battery
temperature of 20 °C. If a temperature sensor is used with the
battery, these values will vary in accordance with the battery
temperature.
High temperature
–> reduction of the threshold values.
Lower temperature –> higher threshold values.
Application
Parallel mode, general charging mode.
19

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis