Herunterladen Inhalt Inhalt Diese Seite drucken

Fuses; Disposal; Technical Data - Truma BGF 10 Gebrauchsanweisung

Boiler gas
Vorschau ausblenden Andere Handbücher für BGF 10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Fuses

The 12 V fuse for the boiler is on the electronic control unit on
the device.
Figure 3
The fine fuse on the electronic control unit must always be
replaced with a fuse of the same type: 1.6 A (slow-acting),
EN 60127-2-3.

Disposal

The appliance must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-Life Vehicle Regulation) must be observed.

Technical data

Determined in accordance with EN 15033 or Truma test
conditions
Manufacturer
Truma Gerätetechnik GmbH & Co. KG
Postfach 1252
85637 Putzbrunn (Munich)
Germany
Protection type
IP21
Water capacity
10 litres
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Type of gas
Liquid gas (propane/butane)
Operating pressure
30 mbar
Nominal heat load
1,6 A
Q
= 1.5 kW (H
); 120 g/h; C
n
i
Heating time from approx. 15 °C to approx. 70 °C
Gas mode: approx. 31 min.
Voltage supply
12 V
Power consumption at 12 V
Ignition: 0.25 A
Heating: 0.21 A
Standby: 0.06 A
Standby – gas consumption
approx. 70 W
Weight without water
7.5 kg
Destination countries
BE, BG, RO, DK, DE, EE, FI, FR, GB, GR, HR, IS, IE, IT, LV, LT,
LU, MT, NL, NO, AT, PL, PT, SE, CH, SK, SI, ES, CZ, HU, CY
E1 10R-05 2604
Subject to technical changes.
Dimensions
All dimensions in mm.
Figure 4
; I
13
3B/P
74
Gas connector
454
347
Water
connections
Electronics
Cowl
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis