Herunterladen Inhalt Inhalt Diese Seite drucken

Dometic MSI 212 Montage- Und Bedienungsanleitung Seite 13

Sinus-wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
SinePower
7.2
Connecting the MSI412 and MSI424
Make sure that a professional fuse is installed between the positive pole (+) and the
inverter. Mind the following values:
• MSI412: 50 A
• MSI424: 25 A
A
NOTICE!
• If no sufficient, professional fuse is installed, the inverter could be
damaged and the guarantee is invalidated.
• Do not reverse the polarity. Reversing the polarity of the connections
will cause a great spark and the internal fuses will melt. These fuses
should only be replaced by a qualified electrician.
➤ To set up the inverter, connect the red cable to the positive pole (+) of the vehicle
battery and the black cable to the negative pole (–) of the vehicle battery.
Make sure the vehicle battery terminals are clean when connecting them.
Connecting the external switch contact to the inverter
➤ Connect the external switch to the remote port according to the wiring diagram
(fig. 4, page 5).
➤ Put the switch (fig. 1 1, page 3) in position "I".
✓ The green status LED lights up (fig. 1 2, page 3) when the switch is closed.
EN
Connecting the inverter
13