6. This is an aquarium circulation pump. Do not use this circulation pump for other than intended use
(i.e.: do not use in swimming pools, bathrooms, etc.). The use of attachments not recommended or sold by
the appliance manufacturer may cause an unsafe condition.
• Do not use this circulation pump in swimming pools or other situations where people are immersed.
• This circulation pump is suitable for use in water temperatures up to 35 °C.
• Do not use this circulation pump with inflammable or drinkable liquids.
7. This circulation pump is suitable for INDOOR/HOUSEHOLD use only. Do not install or store the appliance
where it will be exposed to the weather or to temperatures below freezing.
8. Make sure that the circulation pump is securely installed before operating it. Do not allow pump to run dry.
The circulation pump must be immersed in water completely. This circulation pump must never operate
outside of water.
9. WARNING – For North American market only. This appliance has a polarized plug (one blade is wider than
the other). As a safety feature, this plug will fit in a polarized socket only one way. If the plug does not fit
fully in the socket, reverse the plug. If it still does not fit, contact a qualified electrician. Never use with an
extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature.
10. If an extension cord is necessary, a cord with proper rating should be used. A cord rated for less amperes
or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not
be tripped over or pulled. The connection should be carried out by a qualified electrical installer.
SAVE THESE INSTRUCTIONS
11.
For the complete use and understanding of this product it is recommended that this manual is thoroughly
read and understood. Failure to do so may result in damage to this product.
INTRODUCTION
Fluval Sea CP series circulation pumps are designed to work in small reef aquariums. The
exclusive design guarantees a continuous and powerful water flow with 270° directional flow
capability. The suction cup(s) will safely hold the CP circulation pumps on glass (or acrylic) up
to 10mm - 3/4" thick.
DESCRIPTION (FIG. 1)
A. Upper chamber
B. Impeller
C. Shaft
D. Pump body / Lower chamber
ATTENTION!!!
Fluval Sea Circulation Pumps are specially designed for use in aquariums and tanks for water
movement. It is not a filtration pump. Please refer to your dealer for any other application.
SAFETY INFORMATION
Attention: please verify that all components of the pump are undamaged before putting it into function.
Before any kind of intervention, ALWAYS disconnect electrical supply of the pump and any other
appliance placed in the water. Be sure that the voltage of the mains supply corresponds to the voltage
shown on the unit's label.
CONSERVER CES INSTRUCTIONS
11.
E. Motor mount bracket
F. Suction cup
G. Suction cups
• The pump is intended for indoor use only in water with a temperature of max. 35°C (95°F).
• Do not connect to electrical supply if pump is not completely immersed in water.
• Do not connect to electrical supply if pump is missing parts.
• Do not connect to electrical supply if pump is not positioned using the supplied suction-cup.
• The cord of this pump cannot be replaced or repaired; in case of damage the entire unit must
be substituted.
• Do not cut or pull on the electrical cord.
• Always disconnect from main power supply gently and make sure hands are dry.
• When in operation, make sure that the pump surface is not blocked.
• When in operation, make sure that the pump does not take in sand, as this could seriously
damage the unit and void the guarantee (read carefully the maintenance paragraph)
• Always clean the aquarium side before placing the suctions cup(s), any dirt on the surface
might prevent the suction cup(s) from attaching properly and the pump might slip on the
bottom of the aquarium causing damage to livestock and itself.
• Please keep these instructions in a safe and dry place.
INSTALLATION
Attention: please verify that all components of the pump are undamaged before putting it
into operation. Before any kind of maintenance, always disconnect electrical supply of the
pump and any other appliance placed in the water. Be sure that the voltage of the main power
supply corresponds to the voltage shown on the unit's label. In order to prevent noise and
disturbance caused by vibration we suggest to position the pump avoiding lateral contact with
the aquarium glass or in an upward position on the bottom.
• Unwind the electric cable.
• Insert the pump onto the suction cup (Fig.2).
• Immerse the pump completely and turn it in a vertical position in order to allow any air to
come out of the impeller chamber.
• Attach the pump in the desired location (Fig.3) by pressing firmly to ensure the suction cup(s)
adhere to the glass. Remember to clean the surface before affixing to glass.
• Direct the water flow as desired (Fig. 4).
• Connect to electrical supply.
MAINTENANCE
Attention: Before any kind of maintenance, ALWAYS disconnect electrical supply of the pump
and any other appliance placed in the water.
• Regular cleaning and maintenance will guarantee the pump better and longer performance.
• Remove pump from aquarium.
• Disassemble as shown (Fig.5).
• Clean the impeller assembly removing deposits with a soft brush. Do not use detergents or
solvents.
• Reassemble everything in reverse order, make sure the notches on the pump chambers
correspond and that the motor mount bracket is placed correctly (Fig. 6).
• In case of abnormal noise and /or reduced performance caused by sudden changes in
electricity supply, it is sufficient to restart the pump.
• Pendant qu'elle fonctionne, s'assurer qu'elle n'est pas bloquée par du sable, ce qui
pourrait l'endommager sérieusement et annuler la garantie (lire soigneusement le