N
ELECTRICITY
servicing.
Check and follow the instructions! Non-compliance may result in serious injury or
death! HOLZMANN MASCHINEN machines can not be held liable for accidents if safety
instructions are not be followed!
11.4

Safety devices

In the design of the machine following protective devices are provided:
 Forced operation of the splitting wedge. This measure is intended to avoid kickback of the work-
piece. The setting is in horizontal and vertical direction relative to the saw blade.
 The blade guard is attached to the splitting wedge in order to avoid contact with the blade.
 The blade unit can be submerged entirely under the work table. This you have to remove the
blade guard cover from the riving knife.
 device for locking the setting chosen in the vertical and horizontal direction and in an inclined
position.
 Flanges for tool attachment. They are fixed by a spline to the shaft for the self-detachment of
the tools to avoid the stoppage of the machine.
 nut (left-hand thread!) For tool attachment on the shaft.
 rip fence. Used for precise guiding of the workpiece in the longitudinal cutting. It is also made
of crushable material (aluminum).
 The setting of the parallel ruler is possible without the use of tools; the position is read on a
measuring scale.
 Electronic brake for electrodynamic braking of the motor. Secures the tool in less than 10 sec-
onds to slow down after the drive off.
 Impeccable sharpened tools.
 The use of blunt tools is not permissible due to kickback, overloading the machine and produce
poor surface during machining.
 For cuts less than 120 mm width supplying the material with a push stick must be made, and
the stop bar must be in a flat position.
11.5

Residual risk factors

Also in compliance with all safety regulations and when used following residual risks are considered:
 Risk of injury to the hands / fingers through the panel saw blade during operation.
 Risk of injury from contact with live electrical components.
 Risk of injury or ejection fraction or the panel saw blade panel saw blade parts, especially
case of overload and in the wrong direction.
 Hearing, unless arrangements have been made by the user for hearing protection.
 Risk of injury from kickback of the cuttings, the ejection of the cut material or parts of there.