Check fluid level in the battery and ad-
just if required
Warning
Regularly check the fluid level in acid-filled
batteries.
Unscrew all cell caps.
Where fluid level is too low, top up cells
to the mark provided with distilled water.
Charge battery.
Screw in cell caps.
Install hand spray gun
Connect high pressure hose and spray
pipe to the hand spray gun.
Mount the power nozzle on the spray
pipe. Tighten covering nut firmly.
Connect the high pressure host to the
high pressure connection point of the
machine.
Installing spare high pressure hose
Figures A-C

Water connection

– For connection values refer to technical
specifications
– Observe regulations of water supplier.
Use a fibre-reinforced hose (not included
in standard delivery).
Diameter should be minimum 1".
Connect the hose to the water connec-
tion of the appliance.
Connect the hose to the water tap.
Open the water supply.
Warning
Never operate the high pressure cleaner
when the tap is closed because dry running
can damage the high pressure pump.
suck in water from vessel
– When fitted with the appropriate acces-
sories, this high-pressure cleaner can
draw in surface water, e.g. from water
butts or ponds.
– Suction height max. 1m.
Danger
Never suck in water from a drinking water
container.
Danger
Never suck in liquids which contain solvents
like lacquer thinner, petrol, oil or unfiltered
water. The sealings within the device are not
solvent resistant. The spray mist of solvents
is highly inflammable, explosive and poison-
ous.
Connect suction hose (minimum diame-
ter 1") with filter (accessory) to the water
connection point.
Remove air from appliance before oper-
ation.
Dearating the appliance
Open the water supply.
Start the engine according to the operat-
ing instructions of the engine manufac-
turer.
Unscrew the nozzle.
Switch on the appliance and let it run un-
til the water exiting from the spray pipe is
bubble-free.
Switch off the appliance and fit the noz-
zle again.

Operation

Danger
– The appliance may not be used in areas
where a risk of explosion is present.
– Place the appliance on firm surface.
– The high pressure cleaner must not be
used by children. (Risk of accident on ac-
count of improper use of the appliance).
– The high pressure spray generates high
levels of noise when the appliance is in
use. Risk of hearing impairment. Al-
ways use proper ear-protection aids
while working with the appliance.
– The water jet coming out of the high
pressure nozzle causes the gun to recoil.
Further, an angular spray pipe can cause
additional torque. Hence hold the spray
pipe and gun firmly.