Technical Specifications
Noise immunity
Electromagnetic HF field, ampli-
tude modulated complying with
ENV 50140 / IEC 1000-4-3
Electromagnetic HF field, pulse
modulated complying with ENV
50204
High-frequency sinusoidal com-
plying with ENV 50141:
Power supply cable, LAN cable,
ground connection
Discharge of static electricity
complying with EN 61000-4-2 /
IEC 1000-4-2 (ESD)
Fast transients complying with
EN 61000-4-4 / IEC 1000-4-4
(burst)
µs pulses complying with IEC
1000-4-5 (surge)
CP 5511 Installation Instructions/Product Information
24
80 to 1000 MHz 10V/m 80% AM
(1kHz)
900 MHz 10 V/m 50% ED (200Hz)
0.15 to 80 MHz 10 V 80% AM
4 kV contact discharge
8 kV air discharge
2 kV
2 kV