WimTec Santec PROOF Montage- Und Bedienungsanleitung Seite 25

Spülkasten slk

Werbung

P
Descrição de Funçãos
1
4
3
2
Via Dip-Switch different functions can be individual adjusted.
1
Switch 1 - Flushing
position "ON": Automatic flushing after utilisation
position "OFF": No automatic flushing - only "manual" flushing via close range reflex
Switch 2 - Intermediate flushing
position "ON": At a longer usage, an intermediate flushing will be released
position "OFF": No intermediate flushing
Switch 3 - Hygiene flushing
position "ON": At 3 - 24 hours non-use a hygiene flushing takes place
position "OFF": No hygiene flushing
Switch 4 - Adjustment magnetic lifter/magnetic valve/motor lifter
position "ON": Activation via magnetic lifter or magnetic valve
position "OFF": Activation via motor lifter
Switch 5 - Cistern
position "ON": cistern SanTec SLK
position "OFF": cistern GEBERIT
Switch 6 - Follow-up time ventilator
position "ON": Follow up time of the ventilator lasts 10 min.
position "OFF": Ventilator de-activated
Controller for flushing time
2
Only active, if DIP-Switch 4 is ON!
Flushing time for magnetic lifter/magnetic valve can be adjusted from 1 - 10 secs.
3
Controller for hygiene flushing
Only active, if DIP-Switch 3 is ON! Hygiene flushing from 3 - 24 h adjustable
Active range controller
4
For the adjustment of the infrared active range (adjustable from 30 - 70 cm)
every 10 min.
(adjustment controller for hygiene flushing 3 )
Connection at mains supply
Connection for external ventilator (max. 24V, 15 mA)
Follow-up time 10 Min.
Connection for CWS CleanSeat
Connection for external button
i.e. prop handle with integrated push button
25