PRODUCT DESCRIPTION
1 Bubble level
2 Display
3 Switch on /
activate laser beam/
5
measurement/
7
continuous measurement
(tracking)
8
4 Addition/subtraction
9
/ switch on/off sound
signal
5 Area and volume
calculation
6 Distance measurement by using inclination angle sensor and
Pythagoras Theorem.
7 Reference point setting/unit of measurement.
8 Switch off/clear
9 Strap location
CONDTROL XP2
LASER DISTANCE METER
User manual
Continuous distance measurement (Tracking)
Press and hold button DIST
. The product will take
ON
measurements one after another, showing the last measured
value. Besides it will show maximal and minimal measured
values. To stop measuring press button DIST
ON
. To exit the
mode press button
.
CALCULATIONS
The last measurement can be cancelled by button
made again in modes of area and volume calculation as well as
measurement of distance by using inclination angle sensor and
Pythagoras Theorem. If you double press button
in any
of the above mentioned modes, the product will enter single
distance measuring mode.
CONDTROL XP2
LASER DISTANCE METER
User manual
Calculation of distance by using 2 additional measurements
(Figure 2)
Double press button
. Symbol
will appear on the
display. Make measurements of distance А and В. Press button
DIST
to calculate
Figure 2
length of distance
С. Distance В must
be
perpendicular
to distance С and
cannot be longer
than distance А.
Calculation of distance by using 3 additional measurements
(Figure 3,4)
Distance D can be measured by making 3 additional
measurements.
Press button
3 or 4 times to choose calculation mode.
Symbol
or
will appear on the display. Make
LASER DISTANCE METER
CONDTROL XP2
Congratulations on your purchase of laser distance meter
CONDTROL XP2.
Safety instructions can be found in the end of this user manual
and should be carefully read before you use the product for
the first time.
FUNCTIONS/APPLICATIONS
Laser distance meter XP2 is intended to measure distance,
lengths, heights, calculate area and volume of measured
objects and distance by using inclination angle sensor and
Pythagoras Theorem. The product is suitable for use at both
indoor and outdoor building areas.
SET
1. Laser distance meter – 1pc.
2. Carry pouch with a strap - 1 pc.
3. User manual – 1 pc.
4. Batteries – 2 pcs.
CONDTROL XP2
LASER DISTANCE METER
5
Display
11
2
3
2
4
3
6
6
4
1 Secondary lines for displaying measuring results, maximal and
1
minimal values.
2 Indicator of minimal and maximal measurements
3 Indicator of inclination angle
4 Indicator of measuring mode
5 Indicator of area and volume calculation mode
6 Main line for displaying measuring results
7 Battery charge level
8 Measuring unit
9 Indicator of laser beam
10 Indicator of reference point
11 Indicator of distance measurement by using inclination
angle sensor and Pythagoras Theorem.
CONDTROL XP2
LASER DISTANCE METER
Area
Press button
. Symbol
will appear on the display.
Make 2 measurements one by one (length and width). Area
(composition of length and width) will be calculated and appear
in the main line on the display.
Wall area
By double pressing button
choose wall area calculation
and
mode. Symbol
will appear on display. The height of
walls, which area is to be calculated, should be the same. Make
the first measurement (height of walls). Make the second
measurement (length of 1st wall). Make the third measurement
(length of 2nd wall). Calculated result will appear in the main
line of the display. Total area (calculation of length and width)
of walls, which length has already been measured, will appear in
the main line of the display.
CONDTROL XP2
LASER DISTANCE METER
measurements of distances А, В and С one by one. After the last
made measurement calculation result (distance D) will appear in
the main line on the display.
Figure 3
LASER DISTANCE METER
User manual
SPECIFICATIONS
Working range
Measuring accuracy
Smallest unit displayed
Automatic shutdown
Laser
Instrument
Display backlight
Reference point setting
Continuous distance measuring (Tracking) √
Addition/Subtraction
Area/volume
Calculation by Pythagoras Theorem
Calculation by using inclination angle
sensor
Laser type
Working temperature
Storage temperature
Dimensions
Weight
Power supply
LASER DISTANCE METER
User manual
OPERATION
Switch on/off
7
To switch on the product press button DIST
9
will switch on and enter measuring mode. To switch off the
10
product press and hold button
In order to save battery power the product will switch off
automatically within 3 minutes after the last operation.
1
Reference point
It is possible to set the reference point - from the top or bottom
end of the product.
The default reference point is the bottom end of the product.
8
To choose reference point press button
Indicator
will appear on the display.
Switch on/off sound signal
Press and hold button
during 2 seconds to switch on/off
sound signal.
Measuring unit setting
Press and hold button
to choose measuring unit.
LASER DISTANCE METER
User manual
Volume
Press button
3 times. Symbol
display. Make 3 measurements one by one (length, width,
height). Volume (composition of length, width and height) will
be calculated and appear in the main line on the display.
LASER DISTANCE METER
User manual
Addition/Subtraction
Addition/Subtraction function is used for addition and
subtraction of lengths.
Make a single distance measurement, activate Addition/
Subtraction mode by short pressing button
the second single distance measurement. Calculation result will
appear in the main line on the display. The next measurements
will also be added/subtracted to/from the next measuring
result.
Figure 4
CONDTROL XP2
LASER DISTANCE METER
User manual
* Use a target plate to increase the measurement range during
daylight or if the target has poor reflection properties.
0,05– 70 м*
** Accuracy can decrease in unfavorable conditions, such as
± 2 mm**
intense sunshine or when measurements are made against
1 мм
glossy or transparent surfaces, moving objects, objects with
rough surface.
45 sec
In unfavourable conditions or when measured distance is over
180 sec
100 m the maximum permissible accuracy is calculated in the
following way:
± (Y + 0,25хDх10-3) mm, where
D (mm) - measured distance
Y (mm) - permissible accuracy according to technical data.
INSERT/REPLACE BATTERIES
Insert
the
batteries,
observing
correct
polarity.
Use
alkaline
batteries
only,
both
650 nm, < 1 mW,
batteries must be of
class II
the same brand with
0 °С ... +40 °С
the same charge level.
–20 °С ... +60 °С
Charge level is shown
on
display.
Replace
105х47х27 mm
batteries
when
83 g
see symbol
on the
2х1.5 V AAA LR3
display.
(alkaline)
CONDTROL XP2
LASER DISTANCE METER
User manual
The following unit can be set:
Distance
Area
. The product
ON
0.000 m
0.000 m²
0' 0'' 1/16
0.00 ft²
.
0 1/16 in
0.00 ft²
0.00 ft
0.00 ft²
MEASUREMENT
Single distance measurement
Switch on the product. Short press button DIST
laser beam, point it at the target and press button DIST
consistently.
for single distance measurement.
CONDTROL XP2
LASER DISTANCE METER
User manual
Calculation of distance by using inclination angle sensor and
Pythagoras Theorem
If it is impossible to make direct measurement (there is some
obstruction) required length can be calculated with the help of
inclination angle sensor, 2 or 3 additional measurements.
Calculation of distance by using inclination angle sensor
(Figure 1)
Short press button
angle will appear on the display.
Make measurement of distance А. Length of distance А will
appear in the top line. Value of angle α between distance А
and В will appear
will appear on the
in the middle line.
Length of distance
B will be calculated
and appear in the
main line on the
display. Distance В
is horizontal.
CONDTROL XP2
LASER DISTANCE METER
User manual
MESSAGE CODES
While operation, the following codes/symbols may appear on
the display:
, then make
Message
Cause
301
Distance is out of range
302
Reflected signal is too weak Use reflecting plate
Measuring result cannot
303
be displayed (negative or
exceeds 99999)
Pythagorean theorem
304
calculation error
305
Low battery
306
Temperature is too low
307
Temperature is too high
308
Ambient light is too strong
CONDTROL XP2
User manual
you
CONDTROL XP2
User manual
Volume
0.000 m³
0.00 ft³
0.00 ft³
0.00 ft³
ON
to switch on
again
ON
CONDTROL XP2
User manual
. Symbol
and value of inclination
Figure 1
CONDTROL XP2
User manual
Solution
Keep
in
correct
measuring range
Repeat measurements
Make measurements in
correct succession
Replace batteries
Warm up the product
Cool down the product
Make measurements in
less illuminated zone

Werbung

loading

Inhaltszusammenfassung für CONDTROL XP2

  • Seite 1 FUNCTIONS/APPLICATIONS Laser 45 sec In unfavourable conditions or when measured distance is over Laser distance meter XP2 is intended to measure distance, Instrument 180 sec 100 m the maximum permissible accuracy is calculated in the lengths, heights, calculate area and volume of measured...
  • Seite 2: Safety Regulations

    7) CONDTROL GmbH is not liable for loss of profit or - Do not expose the product to extreme temperatures. EN 60825-1 with a 630- inconvenience associated with a defect of the device, the - If liquids get inside the product first remove the batteries, 670 nm wavelength.
  • Seite 3 Kleinste Anzeige 1 mm BESTIMMUNGSGEMAESSER GEBRAUCH Oberflächen können ebenfalls zu Fehlmessungen beitragen; Der XP2 ist zum Messen von Distanzen, Hoehen, Laengen, der Laserstrahl wird eventuell abgelenkt. Automatisches Abschalten Laserstrahl nach 45 Sekunden Berechnung von Flaechen und Volumina sowie zum Bestimmen...
  • Seite 4: Garantie

    Deutschland die Stellen sofort mit Wasser. Unter extremen Bedingungen - Warnschilder muessen stets sichtbar und erkennbar am 4) Die Condtrol GmbH behaelt sich das Recht vor, nach eigener koennen Batterien auslaufen. Bei Kontakt der Fluessigkeit mit Geraet angebracht sein. Entscheidung das Geraet zu reparieren oder zu ersetzen.
  • Seite 5 DESTINATION DE L’APPAREIL laser 45 sec l’objet cible a des surfaces lisses, transparentes, irrégulières, Le télémètre laser XP2 est destiné à procéder le mesurage de l’appareil 180 sec si l’objet est en mouvement ou bien si des réfractions du rayon de distance, longueur, hauteur, à...
  • Seite 6 Ne pas jeter les outils dans les ordures ménagères! En Nos contacts sur le site www.condtrol.com. - Ne pas viser le soleil avec l’appareil. conformité avec la Directive Européenne 2002/96/CE relative - Préserver l’appareil des chocs, chutes, vibrations fortes,...