Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Installing The Safety Assembly; Appliance Installation; Water Connection - STIEBEL ELTRON SHU 5 SLi comfort Bedienung Und Installation

Vorschau ausblenden Andere Handbücher für SHU 5 SLi comfort:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

INSTALLATION

Installation
9.
Installation
Material losses
!
When using plastic pipework, observe the extreme op-
erating and fault conditions that can occur on the appli-
ance (see chapter "Installation / Specification / Extreme
operating and fault conditions").
f To provide a supply to two washbasins, use the "water dis-
f
tribution tees" (see chapter "Installation / Appliance descrip-
tion / Required accessories").
f Run the connections to the second tap on site, e.g. in 10 mm
f
copper pipe.
9.1

Installing the safety assembly

f Fit the safety assembly in the cold water supply line of the
f
appliance.
f Observe the information on the safety assembly (see chapter
f
"Installation / Safety / Information on the safety assembly").
f Observe the information in the safety assembly installation
f
instructions.
9.2

Appliance installation

f Use the installation template to mark the drill holes (SHU
f
10 SLi supplied separately or SHU 5 SLi | SHU 5 SL GB inside
these instructions).
f Drill the holes and insert suitable rawl plugs.
f
f Secure the wall mounting bracket using suitable screws.
f
f Hang the appliance on the wall mounting bracket.
f
Note
Surplus cable can be stored in the cable compartment.
9.3

Water connection

Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
Material losses
!
When tightening the fittings, counterhold with a suitable
spanner.
www.stiebel-eltron.com
Material losses
!
The appliance may lose its function.
f Never interchange the water connections.
f
f Set the flow rate (see safety assembly instructions).
f
Observe the maximum permissible flow rate with a
fully opened tap (see chapter "Installation / Specifi-
cation / Data table").
Match up the colour coding on the water connections of the tap
and the appliance:
- R.h. side blue = "Cold water inlet"
- L.h. side red = "DHW outlet"
f Secure the tap connections to the appliance.
f
Note
Ensure that the water connections are not kinked during
installation. Prevent any tensioning during installation.
9.4

Power supply

WARNING ELECTROCUTION
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING ELECTROCUTION
In the case of permanent connection to the power supply
via a junction box, ensure that the appliance can be iso-
lated from the mains by an isolator that disconnects all
poles with at least 3 mm contact separation.
WARNING ELECTROCUTION
Ensure that the appliance is earthed.
Material losses
!
The voltage specified on the type plate must match the
mains voltage.
f Observe the type plate.
f
The following electrical connections are permissible:
Connection to a freely accessible
standard socket with matching plug
Permanent connection to an ap-
pliance junction box with earth
conductor
14
19
SHU 5 SLi SHU 5 SL GB SHU 10 SLi
X
-
X
X
SHU 5 | SHU 10 |
X
X
15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Shu 5 sl gbShu 10 sli comfort

Inhaltsverzeichnis