Ensure that the distance from the spindle to the pivot point of the tonearm is exactly
222 mm. Moving the tonearm base in one direction or another will allow you to locate the
correct position. After you have reached the correct position, tighten the tonearm base
again.
Please use the delivered alignment gauge or for more accurate adjustment the professional
cartridge alignment gauge from Clearaudio (Art. NO: AC 005
www.analogshop.de
).
222 mm
Pic. 6: Distance from pivot to stylus

2.5 Further adjustments

2.5.1 Tracking force pre-set up
Please check or adjust the tracking force always without a record on the platter! and
according to the cartridge manufacturer`s specification. Please ensure that the height of the
measuring platform on your tracking force gauge is the same height as a record to get an
accurate measurement. The Clearaudio Smart Stylus Gauge or Clearaudio Weight Watcher
are recommended.
2.5.2 Adjustment of the tonearm height (Vertical-Tracking-Angle / VTA)
You can change the height of your tonearm by loosening the two locking screws on the side
of the tonearm mounting base (Pic. 7). After loosing the screws, you can move the arm up
or down to achieve the required height. Tighten both screws when finished. Please pay
attention to adjust the tonearm tube parallel to the turntable chassis!
Re-check tracking force after adjusting VTA.
Pic. 7: Adjustment of the tonearm height