Function and features

The through-beam sensor detects objects and materials without
contact and indicates their presence by a switched signal.
Range (r): see type label.
Laser radiation; laser protection class 2.
Do not look directly into the beam!
The enclosed labels (warning laser) must be applied in
close proximity to the unit.

Electrical connection

Isolate power, then connect unit (see page 20 or type label).
Load of the function check output (fc output): max. 10mA.

Installation

LEDs red
yellow
push button
green
receiver
Fix the receiver (type OLE-...) in position. Align the transmitter (type
OLS-...) towards the receiver and tighten in the same way. The light
spot must hit the receiver lens.
Maximum range is only possible with precise alignment.