Herunterladen Inhalt Inhalt Diese Seite drucken

Operation - IFM Electronic efector200 OL Laser Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für efector200 OL Laser:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

If the setting of the sensitivity is not possible (e.g. object signal
and background signal are about the same), the red LED flashes
after step 3 for approx. 2s. The unit then passes into the operat-
ing mode with the sensitivity being unchanged.
If the setting button is not activated for 15 minutes during the
programming process, the unit passes automatically into the
operating mode with the sensitivity being unchanged.
Setting of the maximum sensitivity
• Go into the programming mode (step 1).
• Interrupt the light beam.
• Press the setting button twice (see steps 2 and 3).
Programming the output function
Press for 10s.

Operation

Check the safe functioning of the unit. Display by LEDs and by the fun-
ction check output.
LED green is lit
LED yellow is lit
LED red is lit
LEDs
yellow + red
12
receiver
Error in object detection, e.g. maladjustment,
Flash alternately, 2 Hz: output short-circuited.
Flash alternately, 1 Hz: internal malfunction
The red LED starts to flash fast after
2s. Then the yellow and green LEDs
flash alternately. After 8s all LEDs go
off, the output function has chan-
ged from light-on mode to dark-on
mode (or vice versa).
Unit is ready for operation.
Output is switched.
soiling of the lenses.
(output is not switched).

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis