Mount the unit so that the mounting position cannot change (in
particular avoid high vibrations!). Laser units with a very small
light spot diameter are highly focussed; the slightest change in
the mounting position will result in misalignment.
Adjustment aid:
For the alignment the transmitter incorporates an adjustment aid. By
pressing the setting button on the transmitter the intensity of the
transmitted light is increased so that the light spot is clearly visible.
After pressing the button again the transmitted light is set again to
normal intensity. If the button is not pressed again, the transmitted
light is set to normal intensity after about 15 min.
NB: Commissioning
The through-beam sensor is supplied ready to operate (plug and play)
set at the max. sensing range. This is sufficient if the through-beam
sensor can operate with maximum excess gain (highest contrast). The
following setting procedures should only be necessary in less straight-
forward applications, for example if partly transparent objects must be
detected.
Setting of the sensitivity with stationary objects
Activate the programming mode of the unit.
1
Press for about 2s until the red LED flashes.
The red LED goes out; the yellow and green LEDs flash alternately.
The unit is in the programming mode.
receiver
transmitter