Getting started

Installation

Set up the merger on a plane surface or mount it in a 19"
rack with the optional mounting blade. Use four screws to
fasten the mounting blade to the top and bottom of the
housing.

DMX connections

Connect data cables coming out of your lighting control
devices into the male DMX inputs of the merger. Then
connect a data cable to the female DMX output of the
merger and to the first DMX device in the chain.

Connection to the power supply

Connect the power adapter provided to the corresponding
input on the merger and to a mains socket. Thus the
merger is powered on. To switch off the merger and after
the operation, disconnect the mains plug of the power
adapter from the socket, to prevent unnecessary power
consumption.

Initialization

After connecting the merger to the mains, it is initializing.
Once the status indicators A and B start flashing green,
correct DMX512 data is being received. A constant red
light shows that no data is present.

Selecting the output frequency

Use DIP switch 10 to select the output frequency: up = 44 Hz
(LED green), down = 22 Hz (LED orange).