power supply
interface
ID = n
BUTTON CONFIGURATION FOR SPECIAL FUNCTION
It is possible to confi gure a button for a special function, for example to turn the stairs lights on.
To confi gure the button, perform as follows:
Go to advanced confi guration.
Keep the selected button pressed for 3 sec., the door unit emits an acoustic signal to confi rm that the
acquisition has been successfully performed.
PROGRAMMING DATA DELETING
To delete all the data programmed in the advanced confi guration, follow the instructions below:
Go to advanced confi guration.
Keep any button pressed for 5 sec. at least. The door unit emits a fi rst acoustic signal after 3 sec. and
another one longer after 2 seconds, to confi rm the deleting.
AUDIO ADJUSTING
The audio levels are trimmed in factory, so they don't need to be changed in most installations.
If it is necessary to change them, use a screwdriver on the suitable adjusting points.
18
"B"
Secondary call module with 8 buttons
ID = n
AUX dip 2 = 1
offset = 11
Called users: from 11 to 18
Secondary call module with 11 buttons
ID = n
AUX dip 2 = 0
offset = 0
Called users: from 0 to 10
"A"
DS1083-002A
DOOR ELECTRIC LOCK MANAGEMENT
The door units have two terminals for managing the capacitance discharge and hold of the door electric lock
(SE-, SE+). The electric lock is operated in the following cases:
Whenever the hall button is pressed (terminals PA, CT).
When is received a pedestrian crossing door lock release command coming from an apartment station,
according to the confi guration of the dip-switch AUX used to select operating mode "free" or "privacy"
(see "Confi guration" section).
The electric lock activation time can be programmed by rotary switch.
GARAGE DOOR LOCK MANAGEMENT
The doors have two terminals connected to the contacts of a normally open relay which can be used to
control a gate opening control unit (1). The relay is operated for 1 sec. after receiving the garage door
opening command according to the operating mode ("free" or "privacy") as the door lock.
(1) The relay is not suitable to control direct power loads and can only be used as control relay. Refer to the
calling station manual for electrical features.
ILA
Audio repeater device for deaf people driving, in compliance with SOCU0611477A european law.

TECHNICAL SPECIFICATIONS

Power voltage (LINE):
Power voltage (+ -):
Stand-by consumption:
Max. consumption (video call in progress and name tags on):
Name tags ILL output:
Lock output S+ and S-:
Working temperature range::
Reference standards:
DS1083-002A
36 ÷ 48Vdc
36 ÷ 48Vdc
45mA max
250mA max
11 ÷ 13,8Vdc max 200mA
22 ÷ 24Vdc max 200mAdc
-10°C ÷ + 50°C
EN 61000-6-3, EN 61000-6-1