Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - urmet domus 1183/2 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

§
The other functions listed in the "Buttons functions" table will not be lost if the buttons are programmed
for this function because the intercom call is made with the handset off-hook.
INTERCOM FUNCTION IN THE SAME APARTMENT
Go to the apartment station to be programmed as caller (indoor station C1).
Hold the door opener button pressed and pick up the handset. The indoor station C1 outputs a tone to
indicate that programming is in progress.
1
Press the button to be programmed. The indoor station C1 will output a confi rmation tone.
3
Go to the indoor station that the button will call (apartment station C2) and press the door opener button.
The indoor stations C1 and C2 will be beep to indicate that they have been programmed.
Hook up the handset of indoor station C1. It will beep to indicate exit from programming mode.
Check programmed function: pick up the handset C1 and press the programmed button.
Check that the indoor station C2 rings and check audio.
You will need to program indoor station C2 to call C1 to make the opposite call possible.
16
C1
2
C1
C2
§
The other functions listed in the "Button functions" table will not be lost if the buttons are programmed
for this function because the intercom call is made with the handset off-hook.
DOOR PHONE CALL TONE
Five tones can be selected on 2Voice system indoor stations. The
tones can be programmed also by the end user by following the
simple sequence below.
Hold the door opener button pressed. Press and release the button
. The indoor station will play a tone.
Hold the door opener button pressed and press the button
again to change the tone.
Release the door opener button when you have chosen the tone
you want. The tone is now programmed.
FLOOR CALL TONE
Five fl oor call tones can be selected on 2Voice system indoor stations.
The tones can be programmed also by the end user by following the
simple sequence below.
Hold the door opener button pressed. Press and release the button
. The indoor station will play a tone.
Hold the door opener button pressed and press the button again
to change the tone.
Release the door opener button when you have chosen the tone
you want. The tone is now programmed.
PROGRAMMING DATA DELETION
Proceed as follows to delete all optional programming data (intercom calling code):
Hold the door opener button pressed and pick up the handset.
Press
and
at the same time for 3 seconds until you hear the deletion tone.
Release buttons
§
The deletion procedure will not change the programmed calling tones.

TECHNICAL SPECIFICATIONS

Power voltage:
Stand-by consumption:
Max. consumption:
Working temperature range:
Reference standards:
DS1183-004A
DS1183-004A
and
and hang up.
36 ÷ 48Vdc
3,0mA max
70mA max
-5°C ÷ +45°C
EN 61000-6-3, EN 61000-6-1
17