WARNING
: The COMMAND must be connected to the mains with a differential line cut-off switch according
to the regulations in force. Correct operation of the command is assured only for the proper motor for which
it has been manufactured. Improper use relieves the manufacturer from each responsibility.
MANDATORY: cable
out of seeing!
Picture 15

10. ALLOWED / NOT ALLOWED FUELS

Allowed fuels are logs. Use exclusively dry logs (max. content of water 20%). Maximum 2 or 3 logs should be loaded.
The pieces of wood should have a length of ca. 20-30 cm and a maximum circumference of 30-35 cm.
The not worked-out compressed logs must be used with care to avoid overheating that may damage the
appliance, since these have a high calorific value.
The wood used as fuel must have a humidity content lower than the 20% and must be stored in a dry place. Humid
wood tends to burn less easily, since it is necessary a greater quantity of energy to let the existing water evaporate.
Moreover, humid content involves the disadvantage that, when temperature decreases, the water condensates earlier
in the hearth and therefore in the stack causing a remarkable deposit of soot with following possible risk of fire of the
same.
Fresh wood contains about 60% of H
It is necessary to place this wood in a dry and ventilated place (for example under a roofing) for at least two years
before using it.
Besides others, it is not possible to burn: carbon, cuttings, waste of bark and panels, humid wood or wood
treated with paints, plastic materials; in this case, the warranty on the appliance becomes void.
Paper and cardboard must be used only to light the fire.
The combustion of wastes is FORBIDDEN and may damage the product and the chimney, causing health
damages and claims by the neighbourhood owing to the bad smell.
ATTENTION : the continuous and protracted use of aromatic wood (eucalyptus, myrtle etc.) quickly damages the
cast iron parts (cleavage) of the product.

11. LIGHTING

Place the lever of the smoke valve totally to the left (all open). (see CHAP.2 pt. 3)
to light the fire, it is suggested to use small wood pieces together with paper or other traded lighting means.
It is forbidden to use any liquid substance as for ex. alcohol, gasoline, oil and similar.
When wood starts to burn, it is possible to feed it again by opening slowly the door, in order to avoid leaks of smoke,
and adjust the air for the combustion according to the provisions of CHAP. 12.
Position the lever of the smoke valve back to the right (all closed).
Never overload the appliance (see the technical table - max. quantity of fuel that can be loaded / hourly
consumption – (see CHAP. 18).
Too much fuel and too much air for combustion can cause overheating and therefore damage the same.
Never switch on the device when there are combustible gases in the room.
To perform a correct first lighting of the products treated with paints for high temperature, it is necessary to know the
following information:
the construction materials of the involved products are not homogeneous, in fact there are simultaneously parts
in cast iron, steel, refractory material and majolica;
6090710 Rev.10 – EN
O, therefore it is not suitable to be burnt.
2
L
N E E M M
Ph
Marrone
Blu
Giallo / Verde
230 V~ – 50Hz
Picture 16
Marrone
Blu
M
M
TM
Giallo / Verde