CONNECTION AND MAINTENANCE OF VENTILATION

The control unit and the plant must be installed and connected by authorized personnel according to the
standards in force. (see chapter.1)
ATTENTION: the feeding cable must not be in contact with hot parts.
Our inserts are equipped with tangential fans suitable to improve the distribution of heat through the ventilation
exclusively of the installation room (see chapter.6).
The lighting and the adjustment is carried out through the proper standard supplied control unit that has to be installed
far from any direct heat source. The kit is equipped with a thermostat (TM) that lets the fans start when the appliance
is properly heated, and stops them when it is partially cold.
If the control is switched on (pos.
temperature is achieved.
The control unit is provided with a fuse inside in order to protect the engine and the control unit itself.
(Delayed glass fuse 5x20 500 mA (T)).
The selection of the kind of insert to be connected is in the control unit and has to be done by moving the small bridge
as shown hereafter (see chapter .19 – A) before the INSERT starts to operate. This operation must be done
without electric energy!!
CONNECTION TO THE TERMINAL
L / Ph
Power supply
N
Power supply
E
Power supply
E
Motor cable
M
Thermostat cable
M
Motor cable
TM
Internal Thermostat
CONNECTION:
Connect the feeding cable of the switchboard with an electronic bipolar switch respecting at least a 3 mm distance
between the contacts (power supply 230 V~ 50 Hz, it is necessary to provide for the correct connection to the
grounding plant) see chapter 19.
For the connection of the OPTIONAL ventilation kit, see chapter 20.
22
(2) Seal
I
halfway speed – pos.
Phase
Color: Brown
Neutral
Color: Blue
Color: yellow/green
Color: yellow/green
Color: Blue
Color: Brown
INSERTO 60 – 70 – 70 To – 70 Pr – 70 H49
(6) Heat drain grating
(7) Fire-retardant counter-hood
(8) Maximum inclination 45°
(9) Shield wooden parts with
insulating material
(10) Min. distance between Coating and
insert
INSERTO 60 min.: rear 6cm and side 8cm
INSERTO 70 min.: rear 6cm and side 6cm
II
maximum speed), the ventilators work when a pre-set

TECHNICAL FEATURES

POWER SUPPLY
230 V~ ±10% 50/60 Hz
PROTECTION
Internal fuse 500 but T RIT
DIMENSIONS
104 x 75 x 32 mm
CONTAINER
Self-extinguishing ABS IP42 V0
6090710 Rev.10 – EN