Fire-Fighting Safety Measures; First-Aid Measures - LA NORDICA INSERTO 60 Anweisungen Für Die Aufstellung, Den Gebrauch Und Die Wartung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSERTO 60 – 70 – 70 To – 70 Pr – 70 H49
Make sure that the floor can support the weight of the appliance and provide for a proper insulation in case it
is built using flammable material.
Make sure that in the room where it will be installed there is a proper ventilation (presence of air intake)
Avoid the installation in rooms with presence of common ventilation ducts, hoods with or without extractor,
gas devices of type B, heat pumps or the presence of appliances whose simultaneous operation can cause
depression in the room (Ref. Standard UNI 10683/98)
Make sure that the flue and the pipes to which the appliance will be connected are suitable for the operation
of the same.
Always leave the recommended air pocket between the insert and the walls, rear and side min. (see Picture
13 - Picture 14 )
It is recommended that you have your local usual chimney sweeper check both the connection to the stack and the
sufficient air inflow for the combustion in the installation room.
4.

FIRE-FIGHTING SAFETY MEASURES

While installing the appliance, it is necessary to respect the following safety measures (Picture 2):
a) In front of the hearth there must not be any flammable object or construction material sensitive to the heat at
least within 80 cm;
b) Should any appliance be installed on a floor not completely refractory, it is necessary to foresee a fire-
resistant foundation, for example a steel footboard (dimensions according to the local regulations)
The insert must work exclusively with inserted ash drawer.
Solid combustion residuals (ashes) must be collected in an air-tight and fire-resistant container. The device must
never be switched on when there are gaseous emissions or vapors (for example glue for linoleum, gasoline etc.). Do
not deposit flammable materials close to the same.
Warn children that the insert becomes very hot and that it must not be touched.
4.1.

FIRST-AID MEASURES

Should any fire arise in the stack or in the flue:
1. Close the feeding door.
2. Close the registers of combustion air
3. Extinguish the fire using carbon dioxide fire-fighting means (CO
4. Seek immediate intervention of FIRE BRIGADE.
DO NOT EXTINGUISH FIRE USING WATER JETS.
Protection of the floor with
incombustible material.
Flooring in
combustible material .
Picture 2
(3) 10 mm
(1)
(2)
(3) 10÷50 mm
(1)
(3) 10 mm
(2)
6090710 Rev.10 – EN
A = Side limit of the protected area (A=H+20 cm=> 40 cm)
B = Front limit of the protected area.(B=H+30 cm=> 60 cm)
(3) 10 mm
(1)
(3) 10 mm
(2)
(2)
(4)
(1)
(3) 10 mm
(2)
(2)
dust).
2
Height of the hearth
surface from the ground
H
B
A
(1)
(1) Beam;
(2) Refractory insulating material;
(3) Air pocket;
(4) Metallic protection.
(1)
(4)
Picture 3
17