EEx HS Si 4
//
Montage- und Anschlussanleitung / Sicherheitssensor
Mounting and wiring instructions / Safety sensor
Instructions de montage et de câblage / Capteur de sécurité
Istruzioni di montaggio e collegamento / Sensore di sicurezza
Instruções de montagem e instalação / Sensores de segurança
Инструкции Монтаж и Коммутация / Сенсоры безопасности
English
prevented. Please ensure that, even in case of failure, the solenoid in-
terlock cannot be moved from its position. Please ensure that, even in
case of failure, the safety sensor cannot be moved from its position.
For protection against manipulation use oneway safety screws, Torx
with pin, riveting, etc.. When mounting actuator and sensor please ob-
serve the requirements of DIN EN 1088, especially paragraph 5.2 and
5.7! In contrast to magnetic safety sensors with reed contacts the EEx
HS Si 4 can also be mounted on ferro-magnetic material without rele-
vant change in switching distances. Do not install the sensor and the
actuator in strong magnetic fields. The presence of ferromagnetic
chips may reduce sensitivity. Do not expose the components to extre-
me vibrations and shocks. Each safety sensor must be connected to a
fuse with an appropriate current value according to IEC 60127-1-2. The
fuse may be installed in the corresponding power supply or must be
connected separately. The rated fuse voltage must be same or higher
than the maximum supply voltage of the Ex safety sensor. Please also
observe the instructions in the standards EN 292, EN 953 and EN 1088.
Special requirements
The maximum prospective short-circuit current at the location of in-
stallation may not exceed 50 A. The connection cable has to be fixed
and laid in a way that it is protected against mechanical damages (ap-
proval condition X). The cable must be connected inside an enclosure
which meets the requirements of a degree of protection per EN 60079-
0: 2006 and EN 61241-0: 2006, if the connection carried out within a
hazardous area.
Notices
The specified switching distances refer to face-to-face mounted safety
sensors and actuators. Different arrangements are possible, may lead
to different switching distances, however. The maximum possible off-
set between actuator and sensor can be found in the diagram »Axial
offset«. It must be observed that protective guards like doors, grids,
etc. change their position / direction in due time because of mechani-
cal wear. The correct function should be verified by the connected sa-
fety monitoring module. Subject to technical modifications. Do not use
the sensor as mechanical endstop. Any mounting position is possible.
Reconstruction and alterations at the sensor - which might affect the
explosion protection - are not allowed. Furthermore DIN EN 60079-14
and EN 61241-14 have to be applied for the installation of electrical
equipment in explosive areas. Moreover the Atex test certificate and
the enclosed special conditions have to be observed. The described
products have been developed in order to assume safety functions as a
part of an entire plant or machine. A complete safety system normally
covers sensors, monitoring modules, indicator switches and concepts
for safe disconnection. For the integration of the safety switch in the
entire system, the control category determined in the risk assessment
must be strictly observed and respected. Therefore a validation accor-
ding to DIN EN ISO 13849-2 or DIN EN 62061. Furthermore the Perfor-
mance Level and SIL CL can be lower because of the combination of
several safety components and other safety-related devices, e.g. by
serial connection of sensors than the single level. The responsibility
taken by the manufacturer of a plant or machine implies to secure the
correct general function. Subject to technical modifications. Moreover
steute does not assume any liability for recommendations made or im-
plied by this description. From this description new claims for gua-
rantee, warranty or liability cannot be derived beyond the general
terms and conditions of delivery.
Maintenance
With careful mounting as described above, only minor maintenance is
necessary. We recommend a regular maintenance in the following
steps:
1. Check for the switching function
2. Check for tight installation of the actuator and the switch
3. Remove of dirt
français
Destination et emploi
Les capteurs de sécurité EEx HS Si 4 répondent aux exigences des
normes européennes relatives à la protection antidéflagrante selon
EN 60079-0, EN 60079-18, EN 61241-0 et EN 61241-1; ils conviennent
pour l'emploi dans les atmosphères explosibles des zones 1-2 et 21-22
selon DIN EN 60079-14 et EN 61241-14. Les recommandations con-
cernant les dépôts de poussières et températures limites doivent être
respectées, selon EN 61241-14. Le capteur de sécurité EEx HS Si 4 est
prévu pour l'utilisation dans les circuits de sécurité et destiné à la sur-
veillance de protecteurs mobiles selon EN 1088 et EN 60947-5-3. Seul
le système complet : capteur de sécurité / actionneur / module de sé-
curité, permet de remplir les exigences de la norme EN 60947-5-3.
Montage / Raccordement
Le capteur de sécurité ainsi que l'actionneur sont à fixer exclusive-
ment sur des surfaces planes. Seuls des électriciens compétents peu-
vent effectuer le raccordement électrique. Lors du montage, prévoir
un positionnement mécanique approprié de manière à empêcher toute
possibilité de fraude par un autre actionneur ou actionneur de re-
change. Tout déplacement du capteur de sécurité, même en cas de
défaillance, doit être empêché. Fixez l'actionneur à l'aide de vis indé-
montables pour éviter tout démontage frauduleux. Contrairement aux
interrupteurs magnétiques à ampoules Reed, le modèle EEx HS Si 4
peut être monté directement sur une plaque ferromagnétique, sans
que les distances de commutation ne s'en trouvent altérées. Ne pas
monter le capteur et l'actionneur à proximité d'une source magnétique
puissante. Evitez toute accumulation de limailles et copeaux ferroma-
gnétiques. Evitez toute exposition à des vibrations et/ou chocs impor-
tants. Chaque capteur de sécurité doit être raccordé à un fusible
d'intensité nominale appropriée, selon IEC 60127-1-2. Le fusible peut
être implanté dans le boîtier d'alimentation ou raccordé séparément.
La tension nominale du fusible employé doit être égale ou supérieure à
la tension d'utilisation maximale du capteur de sécurité Ex. Les re-
commandations des normes EN 292, EN 953 et EN 1088 doivent être
respectées.