Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

WHAT TO DO IF...

CAUTION!
Before troubleshooting, disconnect the power supply.
Only a qualified electrician or competent person must do the troubleshooting that is not in
this manual.
There are some sounds during normal use (compressor, refrigerant circulation).
Problem
The appliance is noisy.
The compressor operates
continually.
Water flows on the rear
plate of the refrigerator.
Water flows into the re-
frigerator.
Water flows on the
ground.
There is too much frost
and ice.
Possible cause
The appliance is not supported
properly.
The Temperature regulator may
be set incorrectly.
The door is not closed correctly.
The door has been opened too
frequently.
The product temperature is too
high.
The room temperature is too
high.
The FROSTMATIC function is
switched on.
The COOLMATIC function is
switched on.
During the automatic defrosting
process, frost defrosts on the
rear plate.
The water outlet is clogged.
Products prevent that water
flows into the water collector.
The melting water outlet does
not flow in the evaporative tray
above the compressor.
Products are not wrapped prop-
erly.
The door is not closed correctly.
The Temperature regulator may
be set incorrectly.
What to do if...
Solution
Check if the appliance stands sta-
ble (all the four feet should be on
the floor).
Set a warmer temperature.
Refer to "Closing the door".
Do not keep the door open longer
than necessary.
Let the product temperature de-
crease to room temperature be-
fore storage.
Decrease the room temperature.
Refer to "FROSTMATIC function".
Refer to "COOLMATIC function".
This is correct.
Clean the water outlet.
Make sure that products do not
touch the rear plate.
Attach the melting water outlet
to the evaporative tray.
Wrap the products better.
Refer to "Closing the door".
Set a higher temperature.
13

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

S80400kgS80360kg

Inhaltsverzeichnis