User manual // TRIA AS Power Pack
READY
FC
AUDIO
4:
LAMP
6:
FULL, PROP
2:
BIAS
3:
FC
40

Flash readiness

Flash readiness of the power pack is shown by
 READY control lamp 8 turned on (green light)
 modeling lamp turned on when Flash Check mode is
activated (switch 3)
 an acoustical signal, when AUDIO 5 is switched on.

APD system

In case of reducing the flash power, the stored energy will be
discharged by the APD system (Automatic Power Drop). No
flash will be triggered. After switching off, the power packs will
be discharged automatically.

Modeling lamp

The modeling light is turned on and off, respectively, using
switch 4. Turning on of the modeling lamp is only effective
when the connected flash head and modeling lamp are
switched on.
FULL / PROP
When switch 6 is set to "FULL" position, the maximum output
of the modeling lamp is achieved.
To have proportionality between modeling lamp and flash
power output, switch 6 has to be set to "PROP".
The mode of operation is indicated by the control LED.
BIAS
In case of operation with several flash light units it may be of
benefit to adjust the output of the pilot light. To reduce the
modeling light output by one and two f-stops, respectively, set
the BIAS switch 2 to (-1f) and (-2f), respectively. The re-
spective control indicator lights up.
Flash Check
If this mode is switched on using switch 3 (LED indicator lights
up), then the modeling lamp is turned off after a flash and is
turned on after recharging to the adjusted power level. This
shows correct charge as well as readiness to flash.
The flash check mode guarantees that the flash heads have
triggered when more than one flash unit is used.
HENSEL-VISIT GmbH & Co. KG