The admissible load capacity of a flash head will be controlled
by a flash head plug code. In case of connecting an in-
admissible flash head to the power pack, the code will block
flash release. Only flash head extension cables with the plug
code must be used. The cables can be ordered with precise
specification from Hensel-Visit.
Lamp heads / flash heads with halogen lamps which are not
equipped with a cooling fan must not be used. During quick
flash sequences, the flash tubes and therefore also the power
pack would be damaged.
Third party manufacturers
Even though similar lamp sockets and plugs are used by
other manufacturers as well, lamps and flash heads from
these manufacturers must not be connected to the Tria AS
power pack. This requires in every case an adapter cord. Ask
your Hensel agent about suitable adapter cords for your
brand.

Number of flash heads connected

Max. 4 flash heads are allowed to be simultaneously con-
nected to the power pack. The maximum load capacity of the
flash head must not be exceeded.

Power distribution

Distribution of flash power is achieved asymmetrically over
the 2 channels A and B.

Mechanical connection of lamp plugs

 Before connecting lamp plugs, turn the lamp control
switches 16 off and switch the power pack off using the
main switch.
 Only use flawless plugs and sockets.
The lamp plug is locked using a mechanical catch. To do this,
insert the plug into the flash socket 15, slightly tilted forward,
and then press it tightly into the catch at the rear near the
cable duct.
To disconnect the plug, press the catch back and pull the plug
upwards at the back at the cable duct.
User manual // TRIA AS Power Pack