TECHNICAL DATA:

MEASUREMENTS WxHxD: 728x840x520 mm
WEIGHT:
RATED OUTPUT:
FLUE OUTLET:
FUEL:
We are pleased to deliver this fireplace Barun and put it at your disposal.
To achieve the best heating efficiency and performance, please read carefully these Installation
and Operating Instructions.
The fireplace insert is made of high quality cast iron. Joints between burner's individual
component parts are sealed with fire resistant coat. The door and the glass are sealed with
fibreglass material. Underneath the burner there is an ash tray and primary air supply control.
Above the door glazing openings are provided for the supply of secondary air which supports
the combustion and prevents the glass staining.
In the upper part of the firebox, at the entrance into the flue outlet, a "by pass" damper is
installed, which should be opened only when you open the firebox door for the purpose of firing
or reloading. Its function is to prevent smoke from leaking into the room.
Output selection depends on the building insulation grade, weather conditions, exposure of the
building, in particular exposure to wind, etc.
The output of 1 kW is considered sufficient for the heating of a 10 m³ room, with a standard
height of 2,5 m.
For more details see the section entitled: "Space heating capacities".

INSTALLATION INSTRUCTIONS

When installing the fireplace, make sure that relevant local, national and European regulations
are fully complied with. Our liability shall be strictly limited to the delivery of this product in good
operating conditions. After you unpack the product, examine it, and if you spot any damage
return it immediately because we wont accept additional reclamations.
The room in which you place your product should be with sufficient fresh air supply to support
combustion. Regular fresh air supply should be provided through a separate opening near the
fireplace, protected with a non-clogging grid. This is particularly important if an exhauster (hood)
or similar air-consuming unit is installed in the same room.
For connection to the chimney, the use of a common (standard) flue pipe Ø180 mm is
recommended. Installation of a flue pipe furnished with damper is desirable. Smoke pipes should
be placed firmly and tightly both on the smoke fitting and chimney. The flue pipe shall not extend
beyond the chimney lining i.e. shall not protrude into the cross section of the chimney.
Minimum cross section of the chimney shall be 180 mm (~250 cm²) with the height of 5 to 6 m from
the bottom of the firebox. The chimney channel shall be tight, with even cross section over the
entire length and shall protrude 0.5 m above the roof ridge.
185 kg
8kW
Ø 180 mm
Wood
16