Herunterladen Inhalt Inhalt Diese Seite drucken
Endress+Hauser Levelflex FMP5 Serie Einbauanleitung
Vorschau ausblenden Andere Handbücher für Levelflex FMP5 Serie:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation Instruction
I/O module
Levelflex FMP5x, Micropilot FMR5x, Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200
EA00039F/00/A2/21.15
71279012
Instruction is valid for the following spare part set:
Order number
Original spare part set
71108591
I/O module Level 2-wire 4-20 mA, HART, Ex, LP, V1
71187812
I/O module Level 2-wire 4-20mA, HART, Ex, LP, V2
71108594
I/O module, 2-wire, 4-20 mA, HART, Ex, V2
71108595
I/O module Level, 2-wire 4-20 mA, HART, Ex, V1
71108599
I/O module, 2-wire, 4-20mA, HART, PFS, Ex
71108601
I/O module,Level, 2-wire, 2 x 4-20mA, HART, Ex, V1
71207474
I/O module,Level, 2-wire, 2 x 4-20mA, HART, Ex, V2
71108602
I/O module, Flow, 2-wire, 2 x 4-20mA, HART, Ex
71108603
I/O module, 2-wire, PA, PFS, Ex, V1
71164940
I/O module, 2-wire, PA/FF, PFS, EX, V2
71108604
I/O module, Level, 4-wire, DC, 4-20mA, HART, Ex, V1
71207473
I/O module, Level, 4-wire, DC, 4-20mA, HART, Ex, V2
71108605
I/O module, Level, 4-wire, AC, 4-20mA, HART, Ex, V1
71207475
I/O module, Level, 4-wire, AC, 4-20mA, HART, Ex, V2
We recommend that the Installation Instructions be kept with the packaging at all times.
Usage
Levelflex FMP5x
Levelflex FMP5x, Micropilot FMR5x
Levelflex FMP5x, Micropilot FMR5x, Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200
Levelflex FMP5x
Levelflex FMP5x, Micropilot FMR5x, Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200
Levelflex FMP5x
Levelflex FMP5x, Micropilot FMR5x
Promass 200 / TB2, Prosonic Flow 200, Prowirl 200
Levelflex FMP5x
Levelflex FMP5x, Micropilot FMR5x, Promass 200, Prowirl 200, Promag 200
Levelflex FMP5x
Levelflex FMP5x, Micropilot FMR5x
Levelflex FMP5x
Levelflex FMP5x, Micropilot FMR5x
71279012

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Endress+Hauser Levelflex FMP5 Serie

  • Seite 1 Installation Instruction I/O module Levelflex FMP5x, Micropilot FMR5x, Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200 EA00039F/00/A2/21.15 71279012 71279012 Instruction is valid for the following spare part set: Order number Original spare part set Usage 71108591 I/O module Level 2-wire 4-20 mA, HART, Ex, LP, V1 Levelflex FMP5x 71187812 I/O module Level 2-wire 4-20mA, HART, Ex, LP, V2...
  • Seite 2: Designated Use

    Group of persons authorized to carry out repairs I/O module: 2- wire 1, 2, 3 I/O module: 4-wire 1*, 2, 3 1 = Trained customer technician, 2 = Service technician authorized by Endress+Hauser, 3 = Endress+Hauser (send measuring device back to manufacturer) Endress + Hauser...
  • Seite 3: Safety Instructions

    • Threads (e.g. of the cover for the electronics and terminal • Hot surfaces! Risk of injury! Before commencing work, allow the compartment), which have been prepared by Endress+Hauser with system and measuring device to cool down to a touchable an abrasion resistant dry lubrication should not be additionally temperature.
  • Seite 4 I/O module Tool list 3 mm ≤ 3 mm 2.5 Nm 0.5 Nm Replacing I/O module There are two ways for replacing the I/O module: £ 3 mm 0.5 Nm 3 mm 2.5 Nm Grafik Klemme1 Grafik Klemme2 Grafik I/O-Modul 0.5 Nm 3 mm 2.5 Nm...
  • Seite 5: Die Einbauanleitung Ist Für Folgende Ersatzteilsets Gültig

    Analyse Einbauanleitung I/O-Modul Levelflex FMP5x, Micropilot FMR5x, Promass 200 / TB2, Prosonic Flow 200, Promag 200, Prowirl 200 EA00039F/00/A2/21.15 71279012 Die Einbauanleitung ist für folgende Ersatzteilsets gültig: Bestell-Nummer Original Ersatzeil-Set Verwendung 71108591 I/O Modul, Level 2-Draht, 4-20 mA, HART, Ex, LP, V1 Levelflex FMP5x 71187812 I/O Modul, Level 2-Draht, 4-20mA, HART, Ex, LP, V2...
  • Seite 6: Bestimmungsgemäße Verwendung

    Ausführung und die Sicherheit des Geräts nach der Reparatur. Ausführung Ersatzteilset Reparaturberechtigter Personenkreis I/O Modul: 2-Draht 1, 2, 3 I/O Modul: 4-Draht 1*, 2, 3 1 = Ausgebildete Fachkraft des Kunden, 2 = Von Endress+Hauser autorisierter Servicetechniker, 3 = Endress+Hauser (Messgerät an Hersteller zurücksenden) Endress + Hauser...
  • Seite 7: Sicherheitshinweise

    – Mit den jeweiligen Einsatzbedingungen der Geräte vertraut. – nicht in explosionsfähiger Atmosphäre anschließen. – Bei Ex-zertifizierten Messgeräten zusätzlich im Explosionsschutz – nur an Servicegeräte von Endress+Hauser anschließen. ausgebildet. • Die in der Betriebsanleitung aufgeführten Hinweise zum Transport Endress + Hauser...
  • Seite 8 I/O-Modul Werkzeugliste 3 mm ≤ 3 mm 2,5 Nm 0,5 Nm Austausch I/O-Modul Es gibt zwei verschiedene Vorgehensweisen zum Austausch des I/O-Moduls £ 3 mm 0.5 Nm 3 mm 2.5 Nm Grafik Klemme1 Grafik Klemme2 Grafik I/O-Modul 0.5 Nm 3 mm 2.5 Nm Grafik Klemme1 Grafik I/O_Modul2...

Inhaltsverzeichnis