Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - GF 604 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 604:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Troubleshooting

Identification for the housing
The housing nut can be differentiated as followed::
Standard Air connection
The cut-out for the standard air connections is on the opposite from the air connections, and
for the air connections facing in pipe direction the cut-out is offset by 90°.
10
Troubleshooting
Problem
Pipeline and / or
diaphragm valve
deform or expand
Premature wear of the
diaphragm valve or
individual parts
Leakage to the outside
of the union nut
Leakage between valve
body and housing nut
connection
Leakage at seat
Sluggish valve
Valves does not
perform with specified
42
Possible cause of fault
Pipeline forces are too high
Material is not resistant
Loose connection of nut and
valve body
Damage seal
Housing not tightened
properly
Wear of diaphragms
Wear of sealing and / or
spindle
Control pressure is not
selected correctly
Air connection facing pipe direction
Problem fixing
Improve support for the
pipeline.
Select appropriate materials,
see Planning Fundamentals.
Tighten connection finger-
tight.
Replace seal.
Replace diaphragm,
see chapter 9.2
„Disassembly", page 40.
Replace Diaphragm, see
chapter 9.2 „Disassembly",
page 40.
Replace Diaphragm valve
If necessary replace seals
and other functional parts
Check control pressure
Instruction manual