14 electrolux
The technical information are situated in the
rating plate on the internal left side of the ap-
pliance and in the energy label.
Water pressure range
The water pressure must be at least 1 bar
(100kPa)
Highest allowed water pressure 10 bar (1000kPa) If water pressure exceeds 10 bar a reduction
Warning! Do not connect the
appliance in spaces where ambient
temperature can decrease to below
freezing.

INSTALLATION

Read the "Safety Information" carefully
for your safety and correct operation of
the appliance before installing the
appliance.
Positioning
Install this appliance at a location where the
ambient temperature corresponds to the cli-
mate class indicated on the rating plate of
the appliance:
Climate
Ambient temperature
class
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Location
To ensure best performance, if the appli-
ance is positioned below an overhanging
wall unit, the minimum distance between
the top of the cabinet and the wall unit
must be at least 40 mm . Ideally, however,
the appliance should not be positioned be-
low overhanging wall units.
If the cabinet is placed in a corner and the
side with the hinges facing the wall, the dis-
tance between the wall and the cabinet
must be at least 230 mm to allow the door
to open enough so that the equipment can
be removed.
The ventilation space can be:
• directly above the appliance
• behind and above the top cupboard.
In this case, the space behind the top cup-
board must be at least 50 mm deep.
Consult your installer if water pressure is less
than 1 bar.
valve must be fitted (available from your special-
ist shop.
The appliance may only be connected
to drinking water supplies.
The appliance may only be connected
to cold water supplies.
Electrical connection
Before plugging in, ensure that the voltage
and frequency shown on the rating plate cor-
respond to your domestic power supply.
The appliance must be earthed. The power
supply cable plug is provided with a contact
for this purpose. If the domestic power sup-
ply socket is not earthed, connect the appli-
ance to a separate earth in compliance with
current regulations, consulting a qualified
electrician.
The manufacturer declines all responsibility
if the above safety precautions are not ob-
served.
This appliance complies with the E.E.C. Di-
rectives.
50mm