Make sure that you connect the blue
neutral cable to the terminal with a letter
"N" on it. Connect the brown (or black)
phase cable to the terminal which has a
letter "L". Keep the phase cable
connected at all times.
Connection cable
To replace the connection cable use only the special
cable or its equivalent. The cable type is: H05V2V2-F
T90.
Make sure that the cable section is applicable to the
voltage and the working temperature. The yellow /
green earth wire must be approximately 2 cm longer
than the brown (or black) phase wire.
Building In
min. 100 mm
min. 55 mm
30 mm
10 mm
3 mm

Technical information

Hob dimensions
Width
24
min. 650 mm
560 mm
A
11 mm
11 mm
A
B
A) supplied seal
B) supplied brackets
Caution! Install the appliance only on a
worktop with flat surface.
Possibilities for insertion
The panel installed below the hob must be easy to
remove and let an easy access in case a technical
assistance intervention is necessary.
Kitchen unit with door
A
60 mm
B
A) Removable panel
B) Space for connections
Kitchen unit with oven
The electrical connection of the hob and the oven must
be installed separately for safety reasons and to let
easy remove oven from the unit.
594 mm
30 mm
min 20 mm
(max 150 mm)