3.9. SET PARAMETER

Press
key 3 seconds. The screen will shows the menu. Now show menu. Press SET/0~9 sequentially it displays:
rAngE (set limit)
UnIt5 (choose unit)
A-OFF (choose auto power off)
FILt (display filter)
2ero (set auto
→ T
←)
bU22Er (set buzzer)
d (choose division)
d-dP (choose single or dual display)
3.9.1
Set range of auto-zero:
When it shows "rAngE", press
confirm.
When choose "on" and press
increase the current digit, press
turns on, then you can config upper limit with the same procedure; when finishing auto exit and set "over" after setting into weighing.
When low limit > high limit, it displays "oFF", then exit.
Caution: when the display is not stable, no led lights.
Alarming indicate: if bu22er parameter is set to on, alarm will sound if the weigh over the pan is on ok zone.
3.9.2
Change Unit
When shows "UnIt5", press
Units: x9 (kg), pc5 (counting),lb.lb (lb), Lb.o2 (lb.oz), 9 (g).
Counting: when the screen shows "pc5" press
to 0. Then place the sample and press
After to finish the sample "pc5" and the led "
To exit from the counting function, select the unit.
Caution: Enter quantities of up to 30000.
3.9.3
A-oFF (Choose to turn off automatically)
When menu displays A-oFF, press
minutes in zero, auto-off.
3.9.4
Change display filter:
When it displays "FILtX" (FILt1 means one step change display, FILt2 means 3-4 steps change display, FILt3 means 6-8 steps chan-
ge display) Press
to change, press
3.9.5
Set range of auto-zero:
When it displays 2ero, press
division value when n=3000). Press
3.9.6
bUZZEr (set buzze)
When menu displays bU22Er, press
3.9.7
Change division value
When menu displays d, press
14
and then SET to choose "on" or "oFF", "on" is start the function, "oFF" is exit, press
, now you will weigh with limit; led "-"(under limit) lighting, first digit is blinking, press
to confirm and edit next digit; once you finish to set all "-" digits, when you press
, then press SET/0~9 to choose, then press
→ T
←. Now the led
. Pres
and
" is turned on.
to enter, press
to choose "n" o "y", "n" is not auto power off, "y" means, after 10
to confirm and exit.
, now shows 2ero x.x (x.x is the range: 0.5d, 1d, 1.5d, 2d, 2.5d, 3d, 3.5d, 4d, 4.5d, 5d. "d" is the
to choose and
to enter, press
to choose "on" or "oFF", press
to enter, press
to choose division.
to confirm and exit.
ir turned on. Press longer
to introduce the number of pieces that compose the sample.
to confirm.
USER'S MANUAL SS
, led "+"
ON/→ 0
←, shows count and returns
to confirm.
EN
to
once to

Werbung