Werbung

Anschluss
Bedeutung
(Parameter)
SERR_OC_O
DR30: Status module error
SDOS_STEP0_O
DR30: Status dosing cycle in step 0
SDOS_STEP1_O
DR30: Status dosing cycle in step 1
SDOS_STEP2_O
DR30: Status dosing cycle in step 2
SDOS_STEP3_O
DR30: Status dosing cycle in step 3
SDOS_STEP4_O
DR30: Status dosing cycle in step 4
SDOS_STEP5_O
DR30: Status dosing cycle in step 5
SDOS_STEP6_O
DR30: Status dosing cycle in step 6
SDOS_STEP7_O
DR30: Status dosing cycle in step 7
SAFTER_DOS_O
DR30: Status after dosing is active
SCOARSE_ON_O
DR30: Status coarse signal on
SFINE_ON_O
DR30: Status fine signal on
ST_PREDOS_O
DR30: Status timer predosing is running
SEMPTY_ON_O
DR30: Status emptying signal is on
SSTOPPED_O
DR30: Status dosing cycle temporarily
stopped
SCH_STPD_O
DR30: Status check stop
SCH_STP_FOL_O DR30: Status check stop follows
SDOS_CY_ABO_
DR30: Status dosing cycle aborted
O
SN_STEP_W_O
DR30: Status next step is waiting for trigger
STO2_O
DR30: Status tol plus to2 on
STO1_O
DR30: Status tol plus to1 on
STOL_OK_O
DR30: Status tolerance ok
STU1_O
DR30: Status tol minus to1 on
STU2_O
DR30: Status tol minus to2 on
STOL_BAD_O
DR30: Status tolerance bad
SSTILL2_ON_O
DR30: Status stand still 2 on
SSTILL3_ON_O
DR30: Status stand still 3 on
SCHECK_F_O
DR30: Check will follow
SDIS_COMPARA_
DR30: Status disable set point comparator
O
SCONTI_MODE_D
DR30: Status continuous mode on by dosing
OS_O
SRes630_O
DR30: Status reserve
SEND_DOS_CYC
DR30: Status end of one dosing cycle
_O
SEND_CHARGE_
DR30: Status end of charge (unload mode)
O
SGROS_WGT_O
DR30: Actual weight process value gross
SNET_WGT_O
DR30: Actual weight process value net
STARE_WGT_O
DR30: Actual weight process value tare
SGROS_NET_V_
DR30: Actual weight process legal value
O
SGROS_NET_V_1
DR30: Actual weight process legal value x 10
0X_O
STARE_V_O
DR30: Actual weight tare process legal value
SLAST_DOS_V_O DR30: Actual weight process last dosing cycle REAL
SCOUNTER_V_O
DR30: Actual counter value
STOT_V1_O
DR30: Actual total of loaded weight 1
STOT_V2_O
DR30: Actual total of loaded weight 2
Tabelle 4-26
CFC – Anschlüsse des SFTA – DS30 Ausgänge
SIWAREX FTA
Beschreibung der CFCs
Datentyp
Vorbe-
setzung
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
REAL
REAL
REAL
REAL
REAL
REAL
DINT
STRUCT
REAL
Art
B&B
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
+
O
O
+