CV
Range of
Function mapping for function outputs: In order to allocate a
values
function of the digital system to a function output, look for the
33
section where the row of the desired function meets the column of
–
the desired function output. Enter the number found in the
46
respective CV. Ex-works settings are shown in bold print.
CV
Function output:
0-255
33
F0 forward
0-255
34
F0 backward
0-255
35
Function 1
0-255
36
Function 2
0-255
37
Function 3
38
0-255
Function 4
39
0-255
Function 5
40
0-255
Function 6
41
0-255
Function 7
42
0-255
Function 8
50
Bit
Motor configuration
1-3 (0-2)
Select motor type 0-5, enter as decimal number
4,5 (3,4)
not used
6 (5)
0
EMF switch inactive
1
EMF switch active
7 (6)
0
Control switched on
1
Control switched off
8 (7)
0
High-frequency motor control (approx. 23 kHz)
A
B
8
16
8
16
8
16
8
16
8
16
1
2
1
2
1
2
1
2
1
2
31
Ex-works
setting
C
8
32
16
32
32
32
0
32
0
32
4
0
4
0
4
0
4
0
4
0
0 (dec)
0
0
0
E