INVENTOR ATM04S Benutzer- & Installationshandbuch Seite 65

Vorschau ausblenden Andere Handbücher für ATM04S:
Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 258
12.4
t_DRYUP
12.5
t_HIGHPEAK
12.6
t_DRYD
12.7
T_DRYPEAK
12.8
START TIME
12.9
START DATE
AUTO RESTART
13.1
COOL/HEAT MODE
AUTO RESTART DHW
13.2
MODE
14.1
POWER INPUT LIMITATION
15.1
M1 M2
15.2
SMART GRID
15.3
Tw 2
15.4
Tbt1
15.5
Tbt2
15.6
Ta
Ta-adj
15.7
15.8
SOLAR INPUT
15.9
F-PIPE LENGTH
15.10
RT/Ta_PCB
15.11
PUMP_I SILENT MODE
15.12
DFT1/DFT2
16.1
PER_START
16.2
TIME_ADJUST
16.3
ADDRESS RESET
17.1
HMI SET
17.2
HMI ADDRESS FOR BMS
17.3
STOP BIT
15.12 DFT1/DFT2 ALARM function can be valid only with IDU software version higher than V99.
The day for w arming up during floor drying up
The continue days in high temperature during floor
drying up
The day of dropping temperature during floor drying
up
The target peak temperature of w ater flow during
floor drying up
The start time of floor drying up
The start date of floor drying up
Enable or disable the auto restart cooloing/heating
mode. 0=NON,1=YES
Enable or disable the auto restart DHW mode.
0=NON,1=YES
The type of pow er input limitation, 0=NON,
1~8=TYPE 1~8
Define the function of the M1M2 sw itch;
0= REMOTE ON/OFF,1= TBH ON/OFF,2= AHS ON/OFF
Enable or disable the SMART GRID;
0=NON,1=YES
Enable or disable the T1b(Tw 2) ;
0=NON,1=YES
Enable or disable the Tbt1;
0=NON,1=YES
Enable or disable the Tbt2;
0=NON,1=YES
Enable or disable the Ta;
0=NON,1=YES
The corrected value of Ta on wired controller
Choose the SOLAR INPUT;
0=NON,1=CN18Tsolar,2=CN11SL1SL2
Choose the total length of the liquid pipe(F-PIPE
LENGTH);
0=F-PIPE LENGTH
<10m,1=F-PIPE LENGTH≥ 10m
Enable or disable the RT/Ta_PCB;
0=NON,1=YES
Enable or disable PUMPI SILENT MODE
0=NON, 1=YES
DFT1/DFT2 port function:0=DEFROST 1=ALARM
Start-up percentage of multiple units
Adjustment time of adding and subtracting units
Reset the address code of the unit
Choose the HMI;
0=MASTER,1=SLAVE
Set the HMI address code for BMS
HMI stop bit
NOTE
8
4
5
3
5
4
45
30
Hour:the
present
time(not on
the hour +1,
0:00
on the hour
+2)
Minute:00
The present
1/1/2000
date
1
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-2
-10
0
0
0
0
0
0
0
0
0
0
10
10
5
1
FF
0
0
0
1
1
1
1
62
15
1
DAY
7
1
DAY
15
1
DAY
55
1
°C
23:30
1/30
h/min
31/12/2099
1/1/2001
d/m/y
1
1
/
1
1
/
8
1
/
2
1
/
1
1
/
1
1
/
1
1
/
1
1
/
1
1
/
10
1
2
1
/
1
1
/
1
1
/
1
1
/
1
1
/
100
10
%
60
1
MIN
15
1
/
1
1
/
16
1
/
2
1
/