Trouble
No cold water
coming out
Notes:
If any other failures occurred, which need professional tools, in order to avoid danger, the machine must be
repaired or replaced by manufacturer, other maintenance offices or professionals from similar offices.
Product Specification
Technical specification
Model No
Product name
Power supply
Machine Size
(Width*height*depth)
Inlet water temperature range
Purified water flow
Inlet water pressure
Work pressure
Rated power
Possible Causes
Cooling function turned off
Too little water in clean
water cup or clean water
cup taken away
R9 Pro
Reverse Osmosis Water Purifier
220-230V~ 50-60Hz
381mm*357mm*252mm
5-35 ℃
0.3L/min ( 25 ℃)
0-0.04MPa
0.4-0.8MPa
2200W
Solutions
Hold "
" button for 5 seconds to
turn on cooling function
Get cold water until the "
reaches at least one cell
" indicator
17