User's Manual NLG4xx-B

6.3 Universal control inputs

As a further possibility for influence the
charger there are two digital inputs at the
control plug. These functions can be de-
fined by software. (See the software d e-
scription)
One possibility, for example, would be the
use of an external battery management
system to monitor the charging procedure.
The inputs pin 7 and pin 8 from the control
plug can be controlled with a nominal logi-
cal signal from 5 to 15 V against pin 18
(ground). (max. -13V...+40V)

6.4 Status indicator

The charger is also equipped with an out-
put which provides information on its im-
mediate operating status. If the signal at
this connection indicates a logical "1", the
battery will not be charged despite the unit
being connected to the mains supply - the
charger switches to the "Battery charge
not possible" status.
18.02.03 – NLG4xx-B_64.doc
6.3 Universelle Eingänge
Als weitere Möglichkeit zur Beeinflussung des
Ladegerätes stehen am Bedienungsstecker
zwei digitale Eingänge zur Verfügung. Deren
Funktion kann softwaremässig definiert wer-
den. (Siehe Beschreibung der Software)
Denkbar wäre zum Beispiel eine Überwa-
chung der Ladung mittels externem Batterie-
managementsystem.
Die Eingänge an Pin 7 und 8 des Bedienungs-
steckers können mit nominal 5 - 15 V (max. -
13V - +40V) Logiksignalen bezüglich Pin 18
(Ground) angesteuert werden.

6.4 Statusanzeige

Zusätzlich steht auch ein Ausgang für die In-
formation über den momentanen B etriebszu-
stand zur Verfügung. Tritt an diesem Ausgang
eine logische 1 auf, wird die Batterie trotz an-
liegender Netzspannung nicht geladen, das
Gerät wechselt in den Zustand „Batteriela-
dung nicht möglich".