Diagnostic function
Via various diagnostic functions, the hybrid motor
starter is able to identify and signal a range of errors,
such as overcurrent, asymmetry, phase failure or self-
test errors.
A self-test is carried out before each power-on
process. If a problem is detected, the device does not
power on and instead displays the message "Error
during self-test". Errors can be caused by defects in
Status
LED description
OFF
No supply voltage (control supply voltage) present
Operational readiness
Supply voltage (control supply voltage) present
Drive switched on
Detection of a deviation, an insulation fault in the
Error during self-test
peripheral circuits equipment or a fault in the device
— the device must be replaced
Internal error in
Bimetal function: The motor current is higher than
controller or I/O
the nominal motor current specification (e.g. class
devices (maintenance
10A): Cooling time running! (20 minutes)
requirement, NE44)
Countdown of cooling period (20min) only starts
After 2 minutes, the „L" or „R" flashes:
A manual reset is possible.
Error restoring the system state:
Checksum erroneous. The thermal memory of the
bimetal function is set to the max. value. The error
must be manually acknowledged, also in automatic
mode.
Symmetry: The motor currents deviate from each
other by more than 33%.
Phase failure: Phase failure with pending
control voltage
Possible causes: minimum current not achieved,
below 0.06A (0.6A), 0.15A (2.4A), 1.2A (9A)
fault in mains voltage, fuses have been triggered,
motor line interrupted
Blocking: The max. measurable motor current is
exceeded for more than 2s.
Explanation: A = LED switched off / E = LED permanently lit / B = LED fl ashes at a frequency of 2Hz (50:50)

Error acknowledgement

Three different options are available for error acknowl-
edgement.
Manual (set / reset button)
Press the set / reset button on the front of the device.
Revision 6, status 05.2017
the power electronics or insulation faults in periph-
eral equipment. An "Error during self-test" cannot be
acknowledged and is stored internally in the device.
In case of repetition of the "Error during self-test",
the device cannot be put into operation again — it
must be replaced (safety precaution).
If an error is detected, the device immediately
switches to a safe, shutdown state.
To exit the safe, shutdown state, the corresponding
error acknowledgement is required.
PWR
Err
L
Green
Red
Yellow
A
A
A
E
A
A
E
A
E
E
A
A
E
E
A
E
B
E
E
B
A
E
B
B
E
B
A
B
B
E
B
B
A
E
B
B
E
B
A
If the set / reset button is still being pressed after approx.
2s, the hybrid motor starter adopts an error state again. If
the acknowledgement request (actuated set/reset but-
ton) is active for more than 6s, an advanced test is con-
ducted for the power output module and then a switch
performed to the „Parameterization" operating mode.
English.
R
96
95
Error
Yellow
acknowledgement
97
96
A
0
1
A
0
1
A
0
1
E
0
1
A
1
0
not
possible
A
1
0
Automatic
E
1
0
Automatic
B
1
0
Manual
A
1
0
Manual
A
1
0
Automatic
E
1
0
Automatic
A
1
0
Manual
B
1
0
Manual
23