3.
2
Connecting the motor output in the
main circuit
The motor output is connected using a 3-pole plug
connector (included in the scope of delivery).

4. Connecting the control wires

Us
R
L
MAN RES AUT
E
97 96 95
X5
X4
X3
22
1
Click
U
R
MAN
Res
AUT
95
96
97
The 24V DC control supply voltage and control voltage
inputs must be operated with power supply modules
according to DIN 19240 (max. 5% residual ripple)!
In order to avoid inductive or capacitive coupling of
noise emissions where long control wires are used, we
recommend the use of shielded wires.
If you want to clamp two conductors under one
terminal point, you must use conductors with the
same conductor cross section!

5. Functions

Block diagramm
MAN
Reset
RES
Auto -
AUT
reset
Us
T
T
E
R
L
EPLAN-symbol
1/L1 3/L3 5/L3
x2
x1
2/T1 4/T2 6/T3
Visualisation – Status-LEDs
The MOTUS visually indicates its operating status via
four LEDs. The functions of the LEDs are based on the
NAMUR recommendation NE44.
When the control supply voltage is connected, all
LEDs light up once as a LED test.
A green LED (PWR) indicates that the control supply
voltage is "OK".
Left or right rotation of the drive is indicated by a
L
corresponding yellow LED (L or R).
E
An error is indicated by a red LED (Err).
Logic
Reset 2
µP
24
V DC
Reset
& Error
24 V DC
97
96
95
95
96 97
Us
R
L
MAN RES AUT
E
x5
x4
Set /
R L Err PWR
Reset
MOTUS®ContactronControl
L1 L2 L3
6/T3
2/T1
4/T2
x3
9 A
max.

Quicklinks ausblenden: