Service Test Programme; Keyboard Control Unit - Grundig 72010 538 0000 Serviceanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GDV 200

Service Test Programme

GB
The Service Test Programme is divided into 3 different parts:
– Automatic System Test
– Manual System Test
– PC System Test
The basis of these System Tests are the Service Test Levels, which are
carried out automatically with the respective test or can be called up
manually.
The keys illustrated below are located on the left side of the magnetically
fixed cover.
Pause (3)
Previous (2)
Next (1)
1. Automatic System Test
With the Automatic System Test the hardware of the DVD-Player can
be checked without further equipment.
During the Automatic System Test the Service Test Levels, which are
listed in the table, are called and executed. If the DVD-Player is faulty,
"Error" is shown on the display and the Service Test Levels have to be
executed with the Manual System Test or the PC System Test.
Start of the Automatic System Test
Press 2 keys simultaneously
<OPEN/CLOSE> + <PAUSE>
Connect to mains
During the test, the display shows
the number of Levels
which have to be tested.
NO
SET OK
YES
To exit Automatic Systemtest: disconnect the VCR from the mains
Number
Nucleus
Description
on
display
9
VideoColSetupComm
Checks the I
IC7316 on the AV-MUX Board
8
VideoScartSwComm
Checks the I
IC7305 on the AV-MUX Board
7
PapChksFl
Calculate and verify checksum
FLASH memory
6
PapDramWrR
Pattern test of all locations in the DRAM(s)
5
Papl2cDisp
Checks the I
slave processor on the display PCB
4
PapS2bEcho
Checks the I
drive mechanism
3
Papl2cNvram
Checks the I
2
PapNvramWrR
Pattern test of all locations in the NVDRAM
1
CompSdramWrR
Pattern test of all locations in the
SDRAM(s)
GRUNDIG Service
Stop (4)
Open / Close (5)
Play (0)
D
VD
L
C
R
DIGITAL
SURROUND
S
S
S
TITLE
CHAPTER
TRACK
FTS
TOTAL
TRACK
TIME
L
W
R
VCD
SCAN
A-B
REPEAT
SHUFFLE
CHAPTER
TITLE
TRACK
D
VD
L
C
R
DIGITAL
SURROUND
S
S
S
TITLE
CHAPTER
TRACK
FTS
TOTAL
TRACK
TIME
L
W
R
VCD
SCAN
A-B
REPEAT
SHUFFLE
CHAPTER
TITLE
TRACK
D
VD
L
C
R
DIGITAL
SURROUND
TITLE
CHAPTER
TRACK
FTS
TOTAL
TRACK
TIME
S
S
S
L
W
R
VCD
SCAN
A-B
REPEAT
SHUFFLE
CHAPTER
TITLE
TRACK
2
C interface with the
2
C interface with the
2
C interface with the
2
C interface to the
2
C interface with the NVRAM
2. Manual System Test
The Manual System Test is a possibility to check which of the modules
(Keyboard Control Unit, DVD Monoboard or Drive Mechanism) is
faulty. In addition to that, it is possible to check all ERRORS by reading
the ERROR log and the ERROR bits, including the ERRORS which
have appeared in the normal use of the DVD-Player. At the end of the
Manual System Test a Loop Test is started (the Service Test Levels of
the Automatic System Test are running in an endless loop).
For this test the DVD-Player has to be connected to a TV Set (PAL or
Multisystem), to control the results of the Service Test Levels.
To check the results of some Service Test Levels, the System Test
requires interactive actions from the user (e.g. confirmation of a
testpicture or a testsound). For some levels (e.g. levels for testing the
Drive Mechanism functions) the DVD-Player has to be opened to
control the function of the moveable components.
The test only checks functions, which can be checked by the Service
Test Software.
Start of the Manual System Test
Press 2 keys simultaneously
<OPEN/CLOSE> + <STOP>
Switch power ON
Interactive Test

Keyboard Control Unit

Display Test
LED Test
Keyboard Test
Remote Control Test
DVD Monoboard
Picture Test 1
Sound Test 1 / DVD-EURO-AV Test
EURO-AV Loop Test
Sound Test 2
Colour Setup Test
Basic Engine
Version Number
Tray Test
Sledge Test
Disc Motor Test
Focus Test
Radial Test
Jump Test
Tray Test
Error Log & -Bits
Loop Test
Disconnect the VCR from
the mains to end player test
2.1 Interactive Tests
2.1.1 Keyboard Control Unit
Display Test
Service Test Level: DispDisplay
By showing a series of test patterns on the local display, the local
display is tested. To step through all different patterns, the user must
either press PLAY (pattern is OK) or PAUSE (pattern was incorrect) to
proceed to the next pattern. The display of patterns is continued
cyclically manner until the user presses NEXT.
Note that a different sample pattern is used here to show all different
display patterns. All other pattern in this document are simplified for
essentials.
If the user presses NEXT before all display patterns are tested, it will
cause an error in the overall result of the System Test.
Service Test Programme
30 (DispDisplay)
29 (DispLed)
27 (DispKeyb)
28 (DispRc)
23a (VideoColDencOn/Off)
20a (AudioPinkNoiseOn)
54a (VideoScartSwDvd)
54b (VideoScartSwPass)
AudioSinOn
53a (VideoColSetupHi)
53b (VideoColSetupLo)
37 (BeVer)
43a/b (BeTrayOut/In)
41a/b (BeSledgeOut/In)
39a (BeDiscMotorOn)
38a (BeFocusOn)
40a (BeRadialOn)
42a/b/c (BeGroovesIn/Mid/Out)
43a/b (BeTrayOut/In)
31 (LogReadErr)
32 (LogReadbits)
2 - 9

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gmh7800Gdv 200

Inhaltsverzeichnis