Herunterladen Inhalt Inhalt Diese Seite drucken

Dell PowerEdge R515 serie Erste Schritte Mit Dem System Seite 13

Vorschau ausblenden Andere Handbücher für PowerEdge R515 serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
Power
AC power supply (per power supply)
Wattage
Voltage
Heat dissipation
Eight–hard-drive systems
Twelve–hard-drive systems
Maximum inrush current
Batteries
System battery
Physical
Height
Eight– hard-drive systems
Twelve–hard-drive systems
Width
Eight–hard-drive systems
Twelve–hard-drive systems
Depth
Eight–hard-drive systems
Twelve–hard-drive systems
Weight (maximum configuration)
Eight–hard-drive systems
Twelve–hard-drive systems
Weight (empty)
Eight–hard-drive systems
Twelve–hard-drive systems
750 W (optional redundant power supply)
100–240 VAC, autoranging, 50–60 Hz
2200 BTU/hr maximum
2450 BTU/hr maximum
Under typical line conditions and over the
entire system ambient operating range,
the inrush current may reach 55 A per
power supply for 10 ms or less.
CR 2032 3.0-V lithium ion coin cell
8.64 cm (3.4 in)
8.67 cm (3.42 in)
43.66 cm (17.19 in)
44.52 cm (17.53 in)
61.02 cm (24.09 in)
66.46 cm (26.17 in)
22.5 kg (49.5 lbs)
29.0 kg (63.8 lbs)
13.5 kg (29.7 lbs)
15.85 kg (34.87 lbs)
Getting Started With Your System
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis