Operating Manual Spray Valve Controller VC 1200
8 Maintenance and Cleaning
The dispensing controller is maintenance-free Any needed repairs must be performed
by an authorized repair center or only by sending the unit back to VIEWEG GmbH
To clean the unit and the housing, use only dry or damp cloths and never use cleaning
fluids such as gasoline, thinners or any other flammable or corrosive liquid
9 Disposal
At the end of its service life, dispose of the controller in accordance with the applicable
local regulations
Electrical parts can not be disposed along with household waste
According to Directive 2012/19/EU on Waste Electrical and Electronic
Equipment (WEEE), electrical equipment must be returned to the
collection points set up for this purpose in order to be reused
10 Technical Data
Dimensions (WxHxD)
Weight
Dispensing time
Power supply
Operating voltage
Valve control voltage
Compressed air at the inlet
Compressed air at the outlet
Parametereinstellungen und -auswahl
Memory
235 x 75 x 210 mm
ca 1,65 kg
0,01 to 999 seconds
85 to 264 V AC 50/60 Hz
24 V DC
0 bis 24 V DC (PWM)
0 - 7 bar
- Spray air 0 to 7 bar (pressure reducer)
- Control air max 7 bar (inlet pressure)
128 x 64 pixel graphic display
8 program slots
33
VIEWEG
EN