  • DEUTSCH, seite 34
12-24 x 5/8" Phillips Head Screws (4x, included)
Additionally, the W-6000 controller can be installed in a 19-inch server rack. Installation in a server rack requires
the following included items:
6-32 x 1/4" Phillips Head Screws (6x, included)
M6 x 20mm Phillips Head Screws (4x, included)
M6 Cage Nuts (4x, included) or M6 Cage Clips (4x, included)
Figure 2
NOTE: The six 12-24 screws are intended for securing the chassis to the rack. Some racks require different screws which are not
included. Verify that you have the correct screws or fasteners for your rack system before attempting to mount the chassis.
Selecting a Location
The W-6000 controller, like other network and computing devices, requires an "electronics friendly"
environment.
Reliable power
Verify that your electrical outlet is compatible with the W-6000 controller (HW-PSU-400) power supply,
which is rated at 400 W total and is auto-ranging to accept 85 to 264 VAC, at 50 to 60 Hz.
The power cords must be rated to 10 A and conform to grounded electrical standards in the country where the
product is operated.
Use of a power line conditioner or Uninterruptable Power Supply (UPS) can decrease or mitigate problems
caused by power service fluctuations. Verify that the output of any power shaping device is compatible with
the W-6000 controller power supplies based on the information provided above.
Cool, non-condensing ventilation
For proper operation, the W-6000 controller requires an environment with an ambient air temperature
between 0 and 40 ºC (32 to 104 ºF). Humidity must be kept at non-condensing levels between 5 and 95%.
Where a large number of electrical devices are working in the same area, additional air conditioning or air
circulation equipment may be required.
Ample space
For proper air circulation, leave at least 10 cm (4 inches) clearance for the vents on the left, right, front, and
rear of the chassis.
Leave additional space in front of the chassis to access power cords, network cables, and indicator LEDs.
Limited electromagnetic interference
Dell PowerConnect W-6000 Controller | Installation Guide
Rack Mounting Hardware (Telecom Kit Shown)
Left
Bracket
O T
O T
O T
S L
S L
S L
6-32 Flat Head
3
3
Screws
x 8
O T
O T
O T
S L
S L
S L
1
1
12-24 Screws
x 6
Right
Bracket
Installing the Chassis | 11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis