Herunterladen Diese Seite drucken

GEZE GC 302 R Montageanleitung Original Seite 7

Richtungserkennender radar-bewegungsmelde
Vorschau ausblenden Andere Handbücher für GC 302 R:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Recommendation: First,selectthe enhanced functionthat is closestto the requirements and then changethe parameterlevelscorrespondingly.
Enhanced
functions
Key code
Parameter
Direction recognition
Field size
Relayhold interval
Output signal
SMD function
Mounting height
Cross traffic
Interference suppression
0+0
SMD field
size
Field geometry
Configuration of individual parameters
Key
Parameter
Level
code
Enhanced functions
2
Directionrecognition
3*
4
(D+@ Mounting h eight
Fied geometry
2*
1-3
@
Fieldsize
4—6*
7—9
2
3
Reay hold interva
5
6
7
8
9
Outputsignal
2
2
3
4
5
SMD function
6
7
8
9
—3
0+0
SMD field size
4
—6
7-9
CTM
2*-3
(crosstraffic
4
-6
masking)
Filter for
interference
2*
suppression
123457 70705-9-9521 Ä-st.l
Standard
Pavement
ON, forwards
ON, forwards
6
7
Is
0.8 s
Active
Active
Off
Off
Upto 3 m
Upto 3 m
Low
Medium
Off
Off
Wide
Narrow
Shortdescription
Predefined settings for standard
applications (seetable)
Off
Backwards
Forwards
Forwardswith MTO(seechap 7)
High(3—4 m)
Standard(upto 3 m)
Narrow fie d
Wide field
Small
Medium
Large
0.2 s
0.5 s
Short
0.8 s
1.0 s
Medium
1.5s
2.0 s
2.5 s
3.0 s
ong
4.0 s
Active:
The relay picksups when
a detection takes place
Passive: T he relaydrops out when
a detection takes place
Off
05s
IOS
Decreasing sensitivity
1.5s
20s
0.5 s
Constantsensitivity
1.0 s
1.5s
2.0 s
(plusSMD+)
Small
Medium
Large
Off
Low
Medium
Prevention of possible
spurioustripping byfluorescent
Off
tubes
Montageanleitung
Entry hall
Retirement
home
OFF
ON, forwards
6
6
02s
Active
Active
Decreasing,
Off
Upto 3m
Upto 3m
Off
Low
Off
Off
5
Wide
Narrow
5.2.4
Explanation of individualparameters
Field size @/field
geometry
Depending on the field geometry(wide/narrowfie d),the field Sizecan be set
correspondingly.
Narrow
field:
Min. 0.7 x06m
w
Max 27 x 1 9m (WXD)
Specifiedvalues measured with mountingheight2.2 m and inclinationangle 350
SMD function (D+@ and SMD+
SMD= Slow motion detection:Verysmall(quasi-static)movements are detected
as soonasthe sensoris activatedOny whenno moremovements are registered
duringtheset monitoringperioddoesthe sensorrelaythe corresponding signal
to the door controller.Thesensitivity duringthis monitoringperiodcan be set to
decreasing cr constant.
SMD+:Triggersthe sensorwhenvery slow movements occur.
Inthis way, evenobjects<
(350inclination angle)that are
not detectedwith the normaldetectionarea are reliably
identified(retirementhomesetting).In orderto preventthe
door from being kept opentoo cng, the SMD+fie d is half as
arge as the detectionarea
SMD field size 0+0
The SMDfield sizesapproximate y correspond to those of the detectionarea,
ie 0+0+0=0+0
Crosstraffic masking CTM
The CTMpreventsa doorfrom being inadvertentlyopenedby peoplywho only
walk past it but do notwant to enter
Status query with remote control
5.2.5
Thestatusqueryis to find outwhat parameters havebeenset Forthis to take
place,the connection to the sensorhasto be establishedandthe corresponding
keycodehasto be entered.Next,a numerical k ey ightsup that indicatesthe
respective parameterevel.
GC 302 R
Supermarket
High mounting
(984)
ON, forwards
ON, forwards
9
9
1.5s
Is
Active
Active
Decreasing,
Off
Off
Medium
Off
Off
5
Wide
Wide
Wide
field:
w
Min 1.1 xo.6 m (WxD)
Optimumsensorsettings:
Narrow field
—Inclinationang e 300—450
* Factory setting
7

Werbung