Herunterladen Inhalt Inhalt Diese Seite drucken

IKEA FRAMTID HGA2K Bedienungsanleitung Seite 10

Vorschau ausblenden Andere Handbücher für FRAMTID HGA2K:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH
Electrical connection
Before connecting, check that the nominal volt-
age of the appliance stated on the rating
plate, corresponds to the available supply
voltage. Also, check the power rating of the
appliance and ensure that the wire is suitably
sized to suit the appliance power rating (re-
fer to the Technical data chapter).
The rating plate is located on the lower cas-
ing of the hob.
The appliance is supplied with a connection
cable. This has to be provided with a proper
plug, able to support the load marked on the
identification plate (refer to the Technical da-
ta chapter).
The plug has to be fitted in a proper socket. If
connecting the appliance directly to the elec-
tric system, it is necessary that you install a
double pole switch between the appliance
and the electricity supply, with a minimum
gap of 3 mm between the switch contacts.
The double pole has to be of a type suitable
for the required load in compliance with the
current rules.
The connection cable has to be placed in or-
der that, in each part, it cannot reach a 90 °C
temperature. The blue neutral cable must be
connected to the terminal block marked with
"N". The brown (or black) phase cable (fitted
in the terminal block contact marked with "L")
must always be connected to the live phase.
Replacement of the connection cable.
If the connection cable must be replaced, on-
ly a type H05V2V2-F T90 cable must be
used. The cable section must be suitable to
the voltage and the working temperature.
The yellow/green earth wire must be approx-
imately 2 cm. longer than the brown (or
black) phase wire.
To open the terminal block and reach
the terminals, proceed as follows:
1. insert the point of a screwdriver into one
of the two visible protruding part of the
terminal block
2. exert a light pressure and lift
The hob is supplied with a three pole termi-
nal block designed for a 230 V connection.
The yellow/green earth wire must always be
connected to the terminal marked with the
symbol
.
Upon completion, secure the connection ca-
ble with the cable clamp and close the termi-
nal block.
Gas setting conversion
This model is designed for use with natu-
ral gas but can be converted for use
with butane or propane gas providing the cor-
rect injectors. The injectors not supplied with
the appliance have to be ordered from After
Sales Service (refer to the Service chapter).
For data concerning injector replacement,
see chapter "Technical data"
10