SETUP

Always disconnect from the mains before filling the machine. Only use water-based fluids. We
recommend high-quality EUROLITE fluids. Never add flammable liquids. If fluid gets inside the
machine, have it checked by skilled personnel before it is operated.
1
Remove all packing materials from the shipping box. Make sure that there are no packing remnants at
the fog output nozzle.
2
Unscrew the tank cap and fill the tank with fog fluid. Tightly close the tank again.
3
Connect the device to the mains with the power plug.

Installation

Install the device in a well-ventilated area.
• The operation in an insufficiently ventilated room can lead to a condensation of the fog fluid. The resulting
slippery surface can cause accidents.
• Keep a minimum distance of 20 cm around and above the device.
• Furthermore, do not orientate the escape nozzle directly in the direction of the audience's eyes. In order to
create a good effect, there should be a distance between the device and the audience of at least 1.5 m.
• Only install the fog machine on scratch resistant and water resistant surfaces.
• Please make sure that the inclination angle does not exceed 15°.

Overhead Installation

If the device is to be installed overhead, the following safety instructions are binding:
Consider the EN 60335-1:1996 and the respective national norms during the installation!
Installation by authorized dealers only!
Before taking into operation for the first time, the installation has to be approved by an expert!
• The installation of the device has to be built and constructed in a way that it can hold 10 times the weight
for 1 hour without any harming deformation.
• The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
• When rigging, derigging or servicing the device staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
• The operator has to make sure that safety-relating and machine-technical installations:
- are approved by an expert before taking into operation for the first time and after changes before taking
into operation another time
- are approved by an expert after every four year in the course of an acceptance test
- are approved by a skilled person once a year
www.eurolite.de